Lubrication; Electrical Connections; To Switch The Jmd-15 To 230V Operation - Jet JMD-18 Operator's Manual

Jmd series mill / drills
Hide thumbs Also See for JMD-18:
Table of Contents

Advertisement

the mill/drill is level after the fastening hardware
has been tightened.
Lubrication
Lubricate all ball oilers on the machine once daily
with 20W machine oil.
The spindle bearings are permanently sealed and
require no lubrication.
Electrical Connections
CURRENT
CARRYING
PRONGS
~
I
A/
GROUND
D.RONG
Before making any electrical connections, make sure
the power source available is compatible with the
machine. Also, press the Off switch on the front of
the machine before connecting to the power source.
w
e
CZ)
The JMO-15 is rated at 115/230V and comes from
the factory prewired at 115V. This mill/drill comes
with a plug designed for use on a circuit with an
outlet that looks like (A) in Fig. 5. The JMO-15 has a
grounding prong as illustrated in (B). A temporary
adapter (C) may be used to connect the plug to a
two pole receptacle (0) if a properly grounded outlet
is not available. The temporary adapter should only
be used until a qualified electrician can install a
properly grounded outlet. The green colored plug
must be securely fastened to the cover plate screw.
~ROUNDING
~~~
,~,,~
Fig. 5
To switch the JMO-15 to 230V operation:
1. Disconnect the machine from the power
source.
2. Remove the junction box cover on the motor.
3. Change the wires according to the diagram on
the inside of the junction box cover.
4. Replace the junction box cover.
5. Change the plug to one that is rated 230V or
hard wire the power cord.
6.
Change the overload from 18A to
10A Specification.
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jmd-15Jmd-pfn

Table of Contents