EN
Problem
Tool shuts off prematurely.
Tool does not change speed.
Warning in the Run Screen: Tool
offline!
Different torque display in the con-
troller and external transducer.
Work light disabled.
No-load speed not reached.
Expected number of run-downs is
not achieved with one charge of
the battery.
WLAN data communication problems between controller and tool
Problem
No WLAN data communication be-
tween the controller and tool.
14
Possible cause
Operator releases start trigger be-
fore the controller stops the tool.
The fastening time exceeds the
standard time of 10 seconds.
Tool exceeds the angle setpoint.
Speed is the same in all stages.
Tool has not been accepted in the
Tool Settings.
Adjust the torque calibration factor. 1.
Customer's special attachment
was added to tool. The tool
memory must be updated.
Disabled by parameter setting.
Battery voltage is too low.
Battery is not fully charged.
The warning threshold for un-
dervoltage is not set to the mini-
mum value.
High torque is needed during a
fastening sequence, e.g., for
coated fasteners.
Battery has too many charging cy-
cles.
Possible cause
The IP address of the tool is not
correctly entered in the controller.
P2506BA | REV E l 2024-07
Measure
► Make sure that the operator keeps the
start trigger pressed throughout the entire
sequence.
► Increase the fastening time.
► Check the fastening sequence to ensure
that the torque shutoff value and/or angle
setpoint are correct. Adjust as necessary.
► Check whether the fastening joint has
changed significantly.
► Make sure that the speed in the stages is
correct.
1.
Select Navigator > Tool Setup.
2.
Select the line with the tool in the tool list
and press <Tool Settings>.
3.
Press <Accept>.
Select Navigator > Tool Setup.
2.
Select the line with the tool in the tool list
and press <Tool Settings>.
3.
Enter the torque calibration factor at
Torque Calibration using the following for-
mula:
New calibration value =
(external value / tool value) x calibration value
used.
Reprogram tool memory.
Parameterize the tool light on the control-
ler screen: Navigator> Advanced > Tool
Group > Extended Tool Settings.
► To activate the work light:
► Use a fully charged battery.
► Use fully charged battery.
► Reduce the Undervoltage (V) on the con-
trol screen: Navigator > Tool Setup > Tool
Settings > Others > Low Level [V].
► To set the warning threshold:
If a high torque is needed for a longer period of
time, e.g., for several turns, the number of run-
downs that can be achieved with one battery
charge will be significantly reduced.
After 800 charging cycles, the capacity is re-
duced to approx. 60%.
Measure
1.
Check on the control screen: Navigator >
Tool Setup, whether the IP address of the
tool has been entered in the box Type.
2.
Otherwise, mark the line and <Edit>.
IP address of tool – see Tool in submenu
WLAN communication.
>
>