6.1

Use Reaction Bar

In operation, the reaction bar rotates in the opposite direc-
tion to the Output Square Drive and must be allowed to
rest squarely against a solid object or surface adjacent to
the bolt to be tightened. React should be on the end of the
reaction bar. When loosening attach the reaction bar on
the opposite side.
or ue
eaction
o ent
Fig. 1-2: Reaction moment
The supplied reaction bar has been designed to give an
ideal reaction point when used with a standard length
socket. In order to take into account a small difference in
the socket length, the reaction recording can have contact
at any point, in the shaded area of the illustration see Fig.
1-3: Safe Support Window, page 11.
Fig. 1-3: Safe Support Window
If an extra long socket is used it may move the reaction
bar outside the safe reaction window.The standard reac-
tion bar may need to be extended to ensure it remains
wholly within the shaded area.
2
Use of 80 % of maximum torque
Apex Tool Group
Risk of injury
Reaction bar can break due to excessive
stress.
► Torque Reaction should be taken in the
► After changing the reaction bar, make
Note
Severe damage to the tool output
► Do not use standard square drive exten-
6.2
Limitation when using high torque /
soft screw joint
High torques and soft screw joints require a longer break
between screw connections, which is why we recommend
pre-tightening to increase the effectiveness.
inal or ue
Fig. 1-4: Limitation
7

Maintenance

Implement a comprehensive safety maintenance program
to provide regular inspection for all phases of tool opera-
tion and power supply.
Maintenance
after every ...
2
cycles
Daily
500,000
or at least once
a year
P2506BA | REV E l 2024-07
Warning
shaded areas only
sure that it can absorb the maximum
load of the tool.
sions.
ightening Angle
Measures
► Check all connections.
► Visual inspection for general dam-
age.
► Perform a general function test
and watch out for excessive vibra-
tion or unusual noise.
► Send the tool to a certified Sales &
Service Center for assessment.