Download Print this page

Emissions; Troubleshooting - Cleco CellCore CCBPWN Series Instruction Manual

Cordless assembly tool – high torque
Hide thumbs Also See for CellCore CCBPWN Series:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Features
Type of Cooling
Relative humidity
Working height
Degree of protection as per DIN EN60529 (IEC60 529)
Protection class as per DIN EN 61140 (VDE 0140-1)
8.4

Emissions

Order No.
CCBAWN225NB6
CCBAWN750NB6
CCBAWN1000NB6
CCBAWN1350NB8
CCBPWN200D6
CCBPWN500D6
CCBPWN750D6
CCBPWN1000D6
CCBPWN1350D8
CCBPWN2000D8
9

Troubleshooting

Problem
Tool does not start.
Tool not recognized.
Tool doesn't start with counter-
clockwise rotation activated.
Apex Tool Group
Data
Convection (self-cooling)
10 % – 90 %, no condensation
Up to 3000 m (9,843 ft) above sea level
IP40
II
Sound Level
Sound Level
Free Speed
Uncertainty
ISO 15744
[dB(A)]
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
Possible cause
No speed programmed.
Controller is waiting for tool ena-
blement.
Fast-Apps mode disabled.
Self-identification data are not rec-
ognized after tool change.
Software is incorrect.
FastApps mode is activated.
Tool is defective.
With counterclockwise rotation,
parameter for speed is set to
1
0
/min.
P2506BA | REV E l 2024-07
Vibration Level
No Load
ISO 28927-2
[m/s²]
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
±3
<2,5
Measure
► Check Linking group. In the mPro mode,
select Navigator> Standard or Navigator>
Basic.
► Check FastApps. In the FastApps mode:
>
.
► Enable the input Tool Enable or, if not re-
quired, deactivate Tool Enable.
► Enable FastApps mode:
.
Accept Tool Settings again:
1.
Navigator > Tool Setup.
2.
Select the line with the tool.
3.
Select Tool Settings> Accept.
► Check controller and measuring card soft-
ware.
► Disable FastApps mode to connect to the
controller.
► Change tool.
Parameterize Speed left rotation
► Select on the controller Navigator >
Standard > Tool Groups > Settings For
Speed Left Rotation.
1
EN
Vibration Level
Uncertainty
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
>
>
13

Advertisement

loading
Need help?

Need help?

Do you have a question about the CellCore CCBPWN Series and is the answer not in the manual?

This manual is also suitable for: