TECHNICAL INFORMATION
Technical Information
Output Power Letter Codes
Output Power (kW)
1.0
2.0
3.0
3.5
7.0
10.5
14.0
17.5
21.0
24.5
28.0
Cabinet Size (number of modules available) and DC Cable Size
Phases
Module Positions
1ph
1ph
3ph
3ph
3ph
3ph
Charge Profile Codes
Profile Code
Charger Profile
P19
FAST
P22
HDUTY
P21
STDWL
P02
GEL
Number Modules
Standard Cable
Gauge
Max 1
6 mm
2
Max 3
25 mm
Max 2
35 mm
Max 4
70 mm
Max 6
95 mm
70 mm
2
Max 8
1 x 95 mm
Description
Fast profile for flooded battery equipped with airmix. Charger rate up to
0.4 C5. Must set battery capacity, temperature & equalize values and fit
properly programmed Wi-iQ
installed or no Comm, charger will use STDWL profile. Weekly equalization
of 8h is needed. Recommended parameters to set on the charger.
Heavy duty wet cell pulse profile. The charge profile diagnoses the
battery status throughout the recharge phase and adjusts its parameters
to optimize the charge of flooded battery technology. Max 0.25 C5. Auto
battery capacity matching with continuous current loops.
Standard (Water Less
Auto battery capacity matching with Ph1 loops. Can manually set battery
capacity if required. Weekly equalization is needed.
IUI profile. Max 0.17 to 0.22 C5. Auto battery capacity with Ph1 loops. Can
manually set battery capacity if required. Weekly equalization is needed.
(cont.)
1
2
3
1
2
3
4
5
6
7
8
Stand-alone cabinet
Three-slot, 3 kW cabinet
2
Two-slot, 7 kW cabinet
2
Four-slot, 3.5 to 14 kW cabinet
2
Six-slot, max 21 kW cabinet
2
Eight-slot, max 28 kW cabinet.
or
Dual cable for 24/36/48Vdc, single cable for
2
®
battery monitoring device (FAST EU). If not
) wet cell profile. IUI profile Max 0.13 to 0.20 C5.
®
Module Power (kW)
1.0
1.0
1.0
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
Comments
72/80Vdc
5
5
Need help?
Do you have a question about the NexSys+ TC3 IQ and is the answer not in the manual?