Features

• Microprocessor-controlled.
• Able to auto-identify battery's capacity.
• Able to adapt to State of Charge (SoC).
• Compatible with battery voltages of:
1ph
12V
24V
36/48V
Wireless integration with Wi-iQ
monitoring devices.

Technical Information

Name Plate Label Definitions
Item
Description
Serial
Provides date code.
Number
Input voltage frequency. Under
no conditions operate the charger
Hertz
at a different frequency or from a
generator with unstable frequency.
TCX. When "1" indicates a Single
Phase
Phase Charger and "3" indicates a
Three Phase Charger.
Nominal voltage for which this charger
AC Volts
is rated to operate.
Nominal DC output voltage of the
DC Volts
charger.
Actual number of power modules
Modules
installed in the charger cabinet.
DC current that this charger will deliver
to a discharged battery with the
DC Amps
number of power modules installed
and based on the nominal voltage.
4
4
FEATURES
• Individual battery pack recognition and automatic
• Unique profile for charging Thin Plate Pure Lead
• Unique charging profiles for the following
3ph
• Remote access via E Connect™ mobile app to
24/36/48V
72/80V
• Controller Area Network (CAN) communication
96V
120V
• Fully programmable to unique fleet
battery
®
• Battery chemistry agnostic: EnerSys
pairing with the charger.
(TPPL).
NexSys
batteries: NXBLOC; NXSTND; NXSFAST;
®
NXP2V; NXPBLC; ATP2V.
change settings, monitor charger and share data.
capable.
requirements.
Lithium-ion (Li-ion), TPPL, Flooded and Gel
Lead-Acid batteries.
®