Typology
Ring Light Anchor Kit and Pole
Installation Guide
Included components
12ft, 14ft,
16ft, 20ft
Pole height
1x – wooden drill template
Included: hardware is galvanized
12ft, 14ft, 16ft, 20ft (5in) pole: (4) anchor bolts, 3/4"-10 x 17" x 3" hook ,
(8) heavy hex nuts, 3/4" x 10, (8) flat washers, .81 ID" x 1.5" OD x 0.13" thick
25ft (5in/6in) pole: (4) anchor bolts, 3/4"-10 x 17" x 3" hook ,
(8) heavy hex nuts, 3/4" x 10, (8) flat washers, .81 ID" x 2" OD x 0.13" thick
Tools Required
• Safety glasses
• Wrenches, 1-1/4" for 4.5m, 6m or 8m (5in/6in) pole
• Level
LIGHTING LAYOUT RECOMMENDATIONS:
Refer to the product data sheet available at
recommendations for light pole spacing.
Landscape Forms is not responsible for site preparation and footings. The following
chart gives necessary information for calculating proper footing size, depending on the
specified light pole.
WARNING! Pole mounted luminaires must be attached before pole installation. Failure
to do so may cause vibration damage to the pole and will void the pole warranty.
Calculations per AASHTO 1994, assuming base of the pole is at grade level.
Pole Size
5" dia x .125" wall x 12ft
5" dia x .125" wall x 14ft
5" dia x .125" wall x 16ft
5" dia x .125" wall x 16ft
5" dia x .156" wall x 20ft
5" dia x .188" wall x 20ft
6" / 5" dia stepped x .188" wall x 25ft
25ft
Pole height
5in/6in dia
www.landscapeforms.com
for
Wind Speed
Max luminaires
110 mph w/ 1.3 gust
110 mph w/ 1.3 gust
110 mph w/ 1.3 gust
110 mph w/ 1.3 gust
100 mph w/ 1.3 gust
100 mph w/ 1.3 gust
100 mph w/ 1.3 gust
INSTALLATION PROCEDURE FOR ANCHOR BOLTS:
1.
Prepare footing as required by local codes.
2.
Install anchor hooks, hex nuts, washers and wooden template as shown in Fig 3. Level template
in all directions. Note: template thickness is less than base plate thickness. Dimensions given
account for the difference.
3.
After footing has properly cured, remove wooden template. Do not remove lower hex nuts or
washers.
HANDHOLE
ORIENTED ON
SIDE OPPOSITE
OF LUMINAIRE
[457mm]
18"
SIDEWALK
SETBACK
Fig. 1 – Sidewalk setback
Base Overturning
Moment (ft-lbf)
Base Shear (lbf)
1
1896
1
2382
1
2967
2
3485
2
4877
3
4923
3
7293
www.landscapeforms.com
Fig. 2 – Base plate
Fig. 3 – Anchor install detail, 5in or 6in pole
orientation
to luminaire
5" diameter pole
6" diameter base pole
Max luminaire
Max EPA (ft²)
223
1.64
248
1.64
276
1.64
316
2.58
372
2.58
369
3.52
434
3.52
Date: March 16, 2022
Ph: 800.521.2546
weight (lbs)
48
48
48
78
78
118
118
Page 1 of 1