Front Panel
The front panel (Figure 4) is located at the right side of the server system, at the front of the chassis.
The front control panel displays status lights for system status, hard drives, and power supplies.
Callout
Control, Connector, Indicator
A
System Power switch & LED
B
System Reset switch
C
SDINT (System Diagnostic
Interrupt) switch
D
System ID switch and LED (Blue)
E
System Status/Fault LED
(Green/Amber)
26
Description
Toggles system power
LED
State
Off
Power off
On
Power on
Off
S5
On
S0
Resets the system.
Asserts SDINT
System identification switch and light
Indicates system status.
LED
State
Off
Not ready
Green,
Ready
solid
Green,
Ready – Degraded
blinking
Amber,
Critical Alarm
solid
Amber,
Non-Critical Alarm
blinking
ACPI
No
No
Yes
Yes
Description
Post err/NMI Ev/CPU missing
No Alarms
CPU Fault, DIMM killed
Critical of Pwr Flt, Fan, Voltage,
and Temperature failures.
Non-Critical of redundant Pwr
Flt, redundant Fan, Voltage,
and Temperature failures.