Dell 3250 Product Manual page 154

Dell poweredge 3250 servers: product guide
Hide thumbs Also See for 3250:
Table of Contents

Advertisement

Command
Switches
SYS
HEALTH
QUERY
154
Description
Causes the BMC to return a high level version of the system health
status in terse format. The BMC returns a string with the following
format if the command is accepted.
PWR:zzz H:xx T:xx V:xx PS:xx C:xx D:xx S:xx O:xx
Where:
• PWR is system POWER state
• H
is overall Health
• T
is Temperature
• V
is Voltage
• PS
is Power Supply subsystem
• F
is cooling subsystem (Fans)
• D
is hard drive / RAID Subsystem
• S
is physical Security
• O
is Other (OEM)
zzz is: ON, OFF (soft-off or mechanical off), SLP (sleep - used
when it cannot distinguish sleep level), S4, S3, S2, S1, ??
(unknown)
xx is: ok, nc, cr, nr, uf, or ?? where:
• ok = OK (monitored parameters within normal operating ranges)
• nc = non-critical
(warning: hardware outside normal
operating range)
• cr = critical (fatal: hardware exceeding specified ratings)
• nr = non-recoverable (potential damage: system hardware in
jeopardy or damaged)
• uf = unspecified fault (fault detected, but severity unspecified)
• ?? = status not available/unknown (typically because system
power is OFF)