This button allows you to open a currently saved SDR file. Upon selecting this option, all currently
loaded SDRs are deleted and only the SDR loaded from the file are displayed. If the file is not a
valid SDR file, an error message is displayed.
Properties Button
This button will force a refresh of the SDR properties and display them in a dialog. Included in the
properties are: IPMI version, Number of SDRs, Last Add Time, Last Erase Time, and Free Space
Remaining in bytes. If there is an error retrieving the SDR properties, an error message is
displayed.
Reload Button
This button will clear the screen of the currently loaded SDRs and reload the SDRs from the BMC.
This load procedure is identical to the load procedure that occurs when the viewer is opened.

FRU Viewer

The FRU Viewer subtask allows you to view the current FRUs in the system.
NOTE
The FRU Viewer task is only available on the local version of the SMU.
This task is not available when running the remote version.
The FRU Viewer allows you to view the current system FRUs on the target system. The FRU
Viewer task supports the following:
Viewing the current system FRUs
Viewing the current system FRU properties
Saving the selected FRU to a file
Viewing a saved FRU file
When you select the view records subtask from the FRU menu, it immediately retrieves the system
FRUs. In order to discover the system FRUs, the viewer must first scan the system SDRs and
search the records for FRU locations.
After the scan of the SDRs is complete, the viewer starts loading the FRUs. If an error occurs
while searching the SDRs, the viewer will try to load the FRUs based on the locator records found.
The following error is displayed:
Error searching for FRU device locator records, not all FRUs may
be displayed. Updating your system's SDRs may correct this problem
As the FRUs are loaded, a dialog window updates you with the progress. A progress window is
updated for every FRU read. The message displayed is updated for each FRU.
After the FRUs are loaded, the FRU list and FRU area viewer are displayed. By default, the first
FRU in the list is selected and displayed. If there is an error while retrieving the FRUs, the
following message is displayed:
Error reading FRU at Device D Bus B ID I