Command
Switches
SYS GET
BOOTOPT
XX YY ZZ
SYS SET
TCFG
-V XX YY
-N XX YY
SYS RESET
SYS
POWER
OFF
SYS
POWER ON
Description
This is essentially a text version of the IPMI "Get System Boot
Options" command. It allows any of the boot option parameters to
be retrieved.
XX YY ZZ represents the hex-ASCII for the data bytes that are
passed in the Get System Boot Options request.
The BMC returns the data from the command in hex-ASCII format.
See Table 27 for information.
XX - Parameter selector
[7] -Reserved
[6:0] - Boot option parameter selector
YY - Set Selector
[7:0] -Selects a particular block or set of parameters under the
given parameter selector
Write as 00h if parameter does not use a Set Selector
ZZ - Block Selector
Selects a particular block within a set of parameters
Write as 00h if parameter does not use a Block Selector.
Note: As of this writing, there are no IPMI-specified Boot Options
parameters that use the block selector. However, this field is
provided for consistency with other configuration commands and as
a placeholder for future extension of the IPMI specification.
Returns the Terminal Mode Configuration bytes where XX and YY
represent hex-ASCII encodings for the volatile version of data
bytes 1 and 2 as specified in Table 28, and AA BB represent hex-
ASCII encoding of the nonvolatile version.
V:XX YY<output termination sequence>
N:AA BB<output termination sequence>
This command sets the volatile Terminal Mode Configuration. XX
and YY represent hex-ASCII encodings for data bytes 1 and 2 as
specified in Table 28. The BMC returns the same output as for
SYS SET TCFG, above.
This command sets the nonvolatile Terminal Mode Configuration.
XX and YY represent hex-ASCII encodings for data bytes 1 and 2
as specified in Table 28. The BMC returns the same output as for
SYS SET TCFG, above.
Directs the BMC to perform an immediate system hard reset.
Directs the BMC to perform an immediate system power off.
Causes the BMC to initiate an immediate system power on.