/CFG
Uses the specified custom configuration file. If not specified, the name of the CFG
(filename.cfg)
file defaults to MASTER.CFG. The configuration file may be used to load multiple
FRU and SDR files. In the configuration file, each FRU and SDR file name must be
called out. Each FRU area and field to be programmed must also be specified. The
configuration file may be used to prompt or request information from you, and to ask
which FRU areas to program.
/P
Pause the display between blocks of data to prevent the displayed data from scrolling
off the screen. The /P command may be used with all other commands. It causes
the data being displayed on the screen to pause after a pre-determined amount is
written, so that the displayed data does not scroll off the screen. If there is not
enough data to fill a screen, the pause command is ignored.
There are two addressing modes for FRU devices:
Indirect: FRUSDR /D FRU [NVS_TYPE | DEV_CNTR | NVS_LUN | DEVICE_ID]
Direct: FRUSDR /D FRU [NVS_TYPE | DEV_CNTR | NVS_LUN | DEV_BUS |
DEV_ADDR]
NVS_TYPE
The type of EEPROM; Either AT24C02, DS1624S, or IMBDEVICE. If not specified,
IMBDEVICE is assumed.
DEV_CNTR
The controller's IPMB device address; defaults to 'C20'. Must be prefixed by 'C' and must be
three characters in length, including the 'C'.
NVS_LUN
The Logical Unit Number. Must be prefixed by 'L' and defaults to 'L00'. LUN value may be
any number between 0 – 3, though any value except the default is uncommon.
DEVICE_ID
The Device ID; defaults to 00. Used only if NVS_TYPE is IMBDEVICE, (i.e. Indirect
Addressing).
DEV_BUS
The device's bus number; it has no default. Required if NVS_TYPE is not IMBDEVICE (i.e.
Direct Addressing). It has no default value.
DEV_ADDR
The device's address; it has no default. Required if NVS_TYPE is not IMBDEVICE (i.e.
Direct Addressing). It has no default value.
All numbers entered for DEV_CNTR, DEV_ID, DEV_BUS, and DEV_ADDR are interpreted as
hexadecimal values, and must be in the range 0 – FF; the NVS_LUN must be 0, 1, 2 or 3. The
command-line arguments may be specified in any order and if one of the arguments is not
specified, then its default value is used, if it has one. If DEV_BUS and DEV_ADDR are specified,
i.e. Direct Addressing is used, then DEV_BUS is assumed to precede DEV_ADDR. If no
arguments are specified for [Address] then the BMC FRU is displayed.
Example of Indirect addressing:
FRUSDR /D FRU
IMBDEVICE
The utility interprets this as DEV_CNTR = 0xC0, NVS_LUN = 0, DEV_ID = 0;
Because many of these values are the default values, the same result could be accomplished with
the following:
FRUSDR /D FRU CC0 0
CC0
L0
0
65