Figure 15. System Fan Status Led - Dell 3250 Product Manual

Dell poweredge 3250 servers: product guide
Hide thumbs Also See for 3250:
Table of Contents

Advertisement

NOTES
Do not attempt to operate this system with less than a fully populated, six
system fan configuration.
To maintain adequate cooling for system components, the swap process must
be completed in two-minutes. This period only applies to the time that the
fan or power supply is removed from the system, not from the time of failure.
A system fan failure is indicated by the corresponding fan LED and by the Cooling Fault LED on
the front panel. The system fan LEDs are shown in Figure 15. The LED is amber and turns on if a
system fan failure occurs. These LEDs can be seen only when the top cover is removed from the
chassis.

Figure 15. System Fan Status LED

37