Micro Centrifuge
1536
User Manual
Manufacturer: GYROZEN Co., Ltd
.
5F, 15 Arayuk-ro, Gimpo-si, Gyeonggi-do, Republic of KOREA
Tel: +82-2-3452-8966 Fax: +82-2-3471-8174
info@gyrozen.com
http://www.gyrozen.com
European Authorized Representative: OBELISS.A
Boulevard GénéralWahis53, B-1030Brussels, BELGIUM
UM-1536(E)(Rev.8) 2024.04.16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1536 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GYROZEN 1536

  • Page 1 Micro Centrifuge 1536 User Manual Manufacturer: GYROZEN Co., Ltd 5F, 15 Arayuk-ro, Gimpo-si, Gyeonggi-do, Republic of KOREA Tel: +82-2-3452-8966 Fax: +82-2-3471-8174 info@gyrozen.com http://www.gyrozen.com European Authorized Representative: OBELISS.A Boulevard GénéralWahis53, B-1030Brussels, BELGIUM UM-1536(E)(Rev.8) 2024.04.16...
  • Page 2: Table Of Contents

    4.4. Setting ACC/DEC ................................19 4.5. Start / Stop ..................................19 4.6. Pulse(Short Spin) ................................ 20 4.7. Save / Call Program ..............................20 4.8. Setting End Alarm ..............................22 4.9. Manual Lid Release ..............................23 5. Maintenance ............................24 1 | www.gyrozen.com...
  • Page 3 Micro Centrifuges,1536 5.1. Outer Part of Instrument, Chamber, Shaft and Rotor ................24 5.2. Replacement of Fuse ............................... 25 6. Trouble shooting ..........................26 6.1. Check List ..................................26 6.2. Error massage ................................27 7. Equipment Disposal ......................... 30 8. Rotor & Accessories ........................31 9.
  • Page 4: Safety Warnings And Cautions

    Instruction Mark indicating danger and warning Attention and warning for electric shock Mark indicating Biohazard warning Mark indicating earth grounding Indicate a hole for manual lid opening in case of emergency Attention and waring for rotor coupling 3 | www.gyrozen.com...
  • Page 5: Safety Precautions

    3. Always install the equipment in a place where temperature and humidity can be controlled. 4. Before connecting the power, the rated voltage should be checked. 5. Using only Gyrozen Co., Ltd’s rotors, components and accessories ensures optimal performance and safety. We cannot guarantee the reliability or safety of any damage or accidents resulting from the use of components and accessories not provided by us.
  • Page 6: Lifting And Carrying

    -Indoor use -Ambient Temperature: -10 ∼ 40℃ -Room Temperature: 5 ∼ 35 ℃ -Relative humidity: 10 ∼ 90 % -Relative humidity: 30 ∼ 85 % -Atmospheric pressure: 500 ∼ 1060 hPa -Atmospheric pressure: 500 ∼ 1060 hPa 5 | www.gyrozen.com...
  • Page 7: Product Description

    Micro Centrifuges,1536 Product description 2.1 Intended Use The device is used mainly in the laboratory to separate the components through centrifugal force. 2.2 Product Description 1. Lid 2. Power Socket 3. Power Switch 4. Chamber 5. Manual Lid Control 6. Display & Control Panel A/S: 02-3452-8966/ 070-8620-5350/ techsupport@gyrozen.com...
  • Page 8: Technical Specifications

    Imbalance cut-off Safety lid lock Lid drop protection Power supply(V/Hz) 230V~(110V optional), 50/60 Hz Power requirement (VA) Dimension(W x D x H, mm) 240 x 378 x 240 Weight without rotor (kg) 11.9 CE mark Cat. No. GZ-1536 7 | www.gyrozen.com...
  • Page 9: Installation

    ▶ When the lid is open, the display status changes from ▶ The lid is automatically opened with end alarm when the operation is completed. Note! The lid of 1536 is opened or sealed by a motorized system. Therefore, the lid can be sealed by gentle pressing-down. A/S:...
  • Page 10: Install And Remove A Rotor

    Before use, make sure that the rotor is securely fastened to the motor shaft. [Check Rotor Lid installation] If you operate a fixed angle rotor, make sure that the rotor lid is properly locked. If not, it may occur very loud noise and serious damage. 9 | www.gyrozen.com...
  • Page 11: Sample Tube Loading

    Micro Centrifuges,1536 3.4 Sample Tube Loading 1. Before loading sample tubes, check the water drop or any dirt in the rotor hole or adaptor, bucket. ▶ If there is any foreign matter or moisture, remove it with soft dry cloth.
  • Page 12 User Manual Correct loading examples for fixed angle rotors Incorrect loading examples for fixed angle rotor Note! For the safety, the instrument has ‘Imbalance cutout’ function to sense the imbalance of the Loaded tubes. 11 | www.gyrozen.com...
  • Page 13: Operation

    Micro Centrifuges,1536 4. Operation 4.1 Key Functions of Control Panel □ RPM/RCF For automatic conversion of RPM/RCF and to set the speed □ TIME Use to set time, available range up to 99min 59sec (00:00 or continuous) □ ACC/DEC Use toe set the acceleration & deceleration level from 1 to 9 steps ‘0’ in deceleration step means natural deceleration.
  • Page 14 Key-Locked to freeze parameter change Key-Unlocked to change parameters Warning Silent Sound Backlight off □ Numeric Key and others Function Numbers for setting value Enter to set or confirm the values Backspace to delete the number before the insertion point 13 | www.gyrozen.com...
  • Page 15: Setting Rotation Speed

    The rotation speed is indicated as RPM (Rotation per Minute) / RCF (Relative Centrifugal Force). The speed range of 1536 is 500~15,000 rpm and 24~21,583 x g. The RPM and RCF values are indicated on the display at the same time.
  • Page 16 [ENTER] key to complete the setting. ▶ After the setting value is saved, actual value is ‘00000’. ▶ When RCF value is saved, RPM is converted automatically. ▶ If any keys are not touched for 15 seconds, the setting mode is cleared. 15 | www.gyrozen.com...
  • Page 17: Setting Time

    Micro Centrifuges,1536 4.3 Setting Time 4.3.1 Setting Time Time can be set at „Minute‟ and „Second‟ and the operation time is available up to 99 min 59 sec or continuous (00 min 00 sec). Two alternative time counter modes are available. In the normal mode, the time count starts at the point when the [Start] button is touched.
  • Page 18 For exact time control, this instrument can be set with AT SET SPEED mode with counts the run time once the actual run speed value and stops when the deceleration begins. * ALL mode : From t0 to t2 * [AT SET SPEED] mode : From t1 to t2 17 | www.gyrozen.com...
  • Page 19 Micro Centrifuges,1536 4.4 Setting Acceleration / Deceleration (ACC / DEC) Acceleration (level: 1~9) and deceleration (level: 0~9 (0: spontaneous deceleration)) can be controlled according to the sample characteristics. 4.4.1 Setting ACC/DEC 1. Touch [ACC/DEC] button once or twice to set the ‘ACC’...
  • Page 20: Setting Acc/Dec

    When the operation is completed, ‘End’ is shown on the display window and lid is automatically opened with the sign ( ) flash on the display. ▶Touch any key or close the lid to switch ‘End’ display to the main screen. 19 | www.gyrozen.com...
  • Page 21: Pulse(Short Spin)

    Micro Centrifuges,1536 Note! Stop at the Maximum Braking Deceleration Touch the [ ] button twice for the fastest deceleration. And the rotation stops at the maximum deceleration rate (DEC9) regardless of the set DEC value. 4.6 Pulse (Short Spin) This function can be used for the quick and short spin-down. If the touched [Pulse] button is released, the centrifuge decelerates immediately.
  • Page 22 ▶If any keys are not touched for 15seconds, the setting mode is cleared. Note ! Lock Mode All input buttons can be locked for protocol security. When the [PROG] button is kept touched For longer than 2 seconds, all buttons can be locked ( ) or unlocked ( 21 | www.gyrozen.com...
  • Page 23: Setting End Alarm

    Micro Centrifuges,1536 4.8 Setting End Alarm Users can select the preferred end alarm. The end alarm with different sound volume (END VOL) and different repeat time (END LOOP) can be selected. 4.8.1 Setting the Volume of the End Alarm 1. Keep touching the number two [ 2 ] button for 3 seconds to change the sound volume.
  • Page 24: Manual Lid Release

    ▶After the lid is opened, it is recommended to wait until electricity gets back to normal. Note! The manual lid release should be performed only when spinning is completely stopped. If not, it could bring about harmful damage to the operators or the samples. 23 | www.gyrozen.com...
  • Page 25: Maintenance

    2. After using the instrument, take out the rotor from the shaft and clean the shaft with dry soft cloth to keep dry. 3. If the rotor cannot be easily removed from the shaft, do not pull the rotor by force and call a service engineer authorized by GYROZEN Co., Ltd. A/S: 02-3452-8966/ 070-8620-5350/ techsupport@gyrozen.com...
  • Page 26: Replacement Of Fuse

    Fuse Case. 2. If you find the fuse broken or damaged, replace it by the new spare one stored in the fuse case and check out if the power can be turned on. 25 | www.gyrozen.com...
  • Page 27: Troubleshooting

    Can’t close the lid. Remove the dirt at the lid latch and keep the lid completely closed. If the lid is closed by any reasons, please contact GYROZEN service team. Please check if the table and the instrument keep level.
  • Page 28: Error Massage

    Check whether the motor is normally working or not. If the error message does not disappear, please contact a Service Engineer of your local GYROZEN’s partner. If the lid opens while spinning or has any trouble in the lid sensor, this message may come up.
  • Page 29 If the error message does not disappear, please contact a Service Engineer of your local GYROZEN’s partner. If the installed software has any bugs, this message may come up. Contact a Service Engineer of your local GYROZEN‟s partner and get the Firmware Program Error 7 firmware upgrade.
  • Page 30 Please reboot the device. If the error persists, contact service center. - The error is displayed when there is no magnet to detect Imbalance Error 29 Imbalance Magnet Please reboot the device. If the error persists, contact service center. 29 | www.gyrozen.com...
  • Page 31: Equipment Disposal

    Micro Centrifuges,1536 7. Equipment disposal Directive 2012/19/EU is the basis for the disposal of waste electrical and electronic equipment (WEEE) within the European Community. This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not be disposed of with unsorted waste.
  • Page 32: Rotors And Accessories

    Tube Tube capacity(mL) Tube Dimension 16 x 59 16 x 67 (Φ x L, mm) Max. radius (mm)* 85.8 Max. RCF (g-force)* 21,583 * Depending on the size of cap, there is a possibility of not fit-in. 31 | www.gyrozen.com...
  • Page 33 Micro Centrifuges,1536 Fixed Angle Rotor, GREB-M-m2.0-36 - Capacity : 36 x 1.5/2.0 mL (24 outer, 12 inner) plus 12 x 0.2 mL (inner) - Max. RPM / RCF : 15,000 / 21,206 - Hole angle from axis during rotati on : ∠ 45°...
  • Page 34 (Φ x L, mm) Adapter None None Cat No. GAS-m0.2(2) GAS-m0.5(2) Max. radius (mm)* 84.3 84.3 Max. RCF (g-force)* 16,854 18,363 21,206 21,206 * Depending on the size of cap, there is a possibility of not fit-in. 33 | www.gyrozen.com...
  • Page 35 Micro Centrifuges,1536 Fixed Angle Rotor, GREB-s0.2-32 - Capacity : 4 x 8-Tube PCR strips, 32 x 0.2 mL - Max. RPM / RCF : 15,000 / 14,187 - Hole angle from axis during rotation : ∠ 45° - Hole dimension (Ø x L,mm) : 6.5 x 16 - Hole bottom type : Round - Max.