Part 1: GENERAL SPECIFICATIONS
1.5 Electrical Power Requirements
1.5.1 Power Requirements for Steam Heat
Machine Full Load Amps
Operating Currents (440V/60/3 Supply)
Steam Heated
Wash motor
Rinse motor
Drive motor
Control Circuit
Circuit
Motor/Control
1.5.2 Power Requirements for Electric Heat
Machine Full Load Amps
Operating Currents (440V/60/3 Supply)
Wash motor
Rinse motor
Drive motor
Control Circuit
Each heat circuit has a separate power source.
Heat
Circuit
Wash
tank heat
Power Rinse
tank heat
Final Rinse
Booster (40 rise)
(One cannister)
Final Rinse
Booster (70 rise)
(Two cannisters)
Cannister 1
Cannister 2
Total KW for 70 rise is 65.6 KW
4
6.9A
2.7 Amps
2.7 Amps
0.4 Amps
1.1 Amps
Voltage
Booster Rise
Hz/Ph
(Steam)
440/60/3
70
6.9A
2.7 Amps
2.7 Amps
0.4 Amps
1.1 Amps
Voltage
KW
Hz/Ph
(Electric)
440/60/3
20KW
440/60/3
30KW
440/60/3
37.8KW
440/60/3
32.8KW
440/60/3
32.8KW
Machine
Power Requirement
Full Load Amps
(125% Service Factor)
6.9 Amps
Amps
Power Requirement
Full Load
(125% Service Factor)
27 Amps
40 Amps
49.6 Amps
43 Amps
53.8 Amps
43 Amps
53.8 Amps
9.0 Amps
33 Amps
50 Amps
62 Amps