120V CONTROLS
1
SW
OFF
ON
51
3
CB
START
TSK
2CR
3CR
1CR
STOP
3
4
5
6
8
7
N.C.
N.0.
1M
98
8
N.O.
3CR
4
16
N.C.
N.O.
2CR
19
N.C.
DSS
W
3
21
6CR
23
7CR
3
26
FRSW
4
3
WFSW
RFSW
CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz,
REV.
AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION POINT
A
TANK HEAT ADDED TO MOTORS AND CONTROL CIRCUIT
MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.
B
MRA TO BE NC IN NORMAL POSITION
DR.BY
J.NEWTON
SCALE
DATE
SHEET
1
OF
1
23MAR00
2
SEE NOTE 1
SEE NOTE 2
N.O.
MRA
MSW
5CR
1MOL
70
9
10
11
12
N.C.
N.O.
N.C.
RINSE AID/
SANI SIGNAL
PRIME
4CR
15
97
FRV
4
TSR
95
HLRT
17
HC2
N.C.
TSW
96
HLWT
20
HC1
N.C.
R
WT
SET FOR 5 SECONDS
CLUTCH
1
4
2
7
M
6
8
5
OFF DELAY
RT
SET FOR 5 SECONDS
CLUTCH
1
4
2
7
M
6
8
5
OFF DELAY
(IF USED)
TLS
DESCRIPTION
REV.
DATE
BY
6JUNE00
JCN
16OCT00 JCN
TO CUSTOMER
DISCONNECT SWITCH
FUSED FOR 50A MAX. AT
440/60/3.
PL
L1
DETERGENT
SIGNAL
1M
IF USED
2MOL
3MOL
4MOL
13
99
14
2M
3M
4M
(IF USED)
98
TKL
2
L1
FU1
P1
1CR
22
1
!!!!!! WARNING !!!!!!
25
2CR
2
MULTIPLE POWER SOURCES ARE PRESENT
IN THIS CABINET. DISCONNECT ALL POWER
SOURCES PRIOR TO SERVICING.
28
3CR
29
4CR
30
5CR
2
6CR
31
32
7CR
DESCRIPTION
DATE
BY
!!!!!! WARNING !!!!!!
MULTIPLE POWER SOURCES ARE PRESENT
IN THIS CABINET. DISCONNECT ALL POWER
SOURCES PRIOR TO SERVICING.
L2
L3
GND
1MOL
1M
L1
42
33
L2
43
34
DRIVE
MOTOR
L3
44
35
2MOL
2M
L1
45
36
L2
46
37
WASH
L3
47
38
MOTOR
3MOL
3M
L1
48
39
L2
49
40
RINSE
MOTOR
L3
50
41
4MOL
4M
L1
51
54
L2
52
55
MRA
MOTOR
(IF USED)
L3
53
56
HC1
80
81
10kW
82
WASH TANK
HEATERS
83
L3
84
10kW
FU2
85
P2
440V
T1
120V
2
TO CUSTOMER
DISCONNECT SWITCH
86
FUSED FOR 50A MAX. AT
440/60/3.
87
10kW
GND
88
2L1
2L2
2L3
HC2
RINSE TANK
89
HEATERS
90
10kW
91
92
93
10kW
94
B
The Dishwashing Machine Specialists
1CR
DOOR SAFETY SWITCH HOLD-IN RELAY
2CR
WASH TANK FLOAT HOLD-IN RELAY
3CR
RINSE TANK FLOAT HOLD-IN RELAY
4CR
FINAL RINSE SWITCH RELAY
5CR
TABLE LIMIT SWITCH RELAY
6CR
WASH TANK FLOAT SWITCH RELAY
7CR
RINSE TANK FLOAT SWITCH RELAY
1M
DRIVE CONTACTOR
1MOL
DRIVE MOTOR OVERLOAD
2M
WASH CONTACTOR
2MOL
WASH MOTOR OVERLOAD
3M
RINSE CONTACTOR
3MOL
RINSE MOTOR OVERLOAD
4M
MRA CONTACTOR
4MOL
MRA MOTOR OVERLOAD
BC1
BOOSTER HEATER CONTACTOR
CB
CIRCUIT BREAKER
DSS
DOOR SAFETY SWITCH
FRSW
FINAL RINSE SWITCH
FRV
FINAL RINSE FILL VALVE
FU-
FUSE-TRASNSFORMER
HC1
WASH TANK HEAT CONTACTOR
HC2
RINSE TANK HEAT CONTACTOR
HLRT
HIGH LIMIT RINSE TANK
HLWT
HIGH LIMIT WASH TANK
KR
KEYED RESET SWITCH
LRTT
LOW RINSE TEMPERATURE TIMER
MSW
MOTOR STOP SWITCH
MRA
MACHINE RACK ADVANCE LIMIT SWITCH
PL
POWER ON LIGHT
RFSW
RINSE TANK FLOAT SWITCH
R
RINSE TANK DOOR SAFETY SWITCH
RL
RESET LIGHT
RT
RINSE TANK FLOAT TIMER
SW
POWER SWITCH
T1
440V:120V TRANSFORMER
TKL
LOW TEMP INDICATOR LIGHT
TLS
TABLE LIMIT SWITCH
TSB
BOOSTER THERMOSTAT
TSK
LOW TEMPERATURE CUT-OFF THERMOSTAT
TSR
RINSE TANK THERMOSTAT
TSW
WASH TANK THERMOSTAT
W
WASH TANK DOOR SAFETY SWITCH
WFSW
WASH TANK FLOAT SWITCH
WT
WASH TANK FLOAT TIMER
NOTES
1. REMOVE JUMPER ACROSS WIRES 70
AND 9 WHEN RACK ADVANCE TABLE IS
USED.
2. REMOVE JUMPER ACROSS N.O. 5CR
CONTACT WHEN TABLE LIMIT SWITCH IS
USED.
DIAGRAM STATE
POWER OFF
DOORS CLOSED
TANKS EMPTY
END OF CYCLE
USN-72
ELECTRIC
701697
REV.
B
**

Advertisement

Table of Contents
loading

This manual is also suitable for:

250-usn-72185-usn-72135-usn-7285-usn-7260-usn-72