Champion USN-72 Technical Manual page 153

High temperature two tank rack conveyor dishwasher with mran 90
Hide thumbs Also See for USN-72:
Table of Contents

Advertisement

SUPPLY CONNECTION #2
CUSTOMER SUPPLIED 440/60/3
50A AT 90°C
MIN. WIRE RATING
MAIN CONTROL
CABINET REMOTELY
LOCATED
63
TO TB5-1
50A AT 90°C
MIN. WIRE RATING
3 - WIRES FOR RINSE TANK
64
TO TB5-2
HEATER WIRING
NUMBERED 63, 64, 65
SEE TERMINAL BLOCK TB-5
DETAIL AT RIGHT.
65
TO TB5-3
35A AT 90°C
60
TO TB4-1
MIN. WIRE RATING
61
3 - WIRES FOR WASH TANK
TO TB4-2
HEATER WIRING
NUMBERED 60, 61, 62. SEE
62
TERMINAL BLOCK TB-4
TO TB4-3
DETAIL AT RIGHT.
33
TO TB3-1
34
TO TB3-2
35
TO TB3-3
15A AT 90°C
36
MIN. WIRE RATING
TO TB2-1
37
TO TB2-2
9 - WIRES FOR MOTOR WIRING
38
NUMBERED 33-41
TO TB2-3
ADD 3 MOTOR WIRES
NUMBERED 54-56 FOR MODELS
39
WITH OPTIONAL MRA TABLE.
TO TB3-4
SEE TERMINAL BLOCK TB-2
40
AND TB-3 DETAIL AT RIGHT.
TO TB3-5
41
TO T35-6
54
TO TB3-7
55
TO TB3-8
56
TO TB3-9
CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz,
REV.
AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION POINT
REMOVE THI R D ELEC CONNECTI O N. ADD NOTE & TB2 / TB3 DETAI L . RESI Z E FOR BETTER CLARI T Y
A
MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.
B
COMPLETE REVISION TO SHOW TERMINAL BLOCK WIRING CONNECTIONS
DR.BY
J.MCALLISTER
SCALE
NONE
DATE
7OCT03
SHEET
1
OF
1
SUPPLY CONNECTION #1
CUSTOMER SUPPLIED
440/60/3
45A AT 90°C
MIN. WIRE RATING
GND
GND
1L1 1L2 1L3
2L1
2L2 2L3
RINSE HEATER
HC2
INPUT BLOCK
CONTACTOR
RINSE AID SIGNAL
WASH HEATER
CONTACTOR
HC1
DETERGENT SIGNAL
MOTOR CONTACTORS
DRIVE
WASH
RINSE
MRA
42
43
44
45
46
47
48
49
50
51
52
53
1M
2M
3M
4M
NOTES:
IF USED
OPTIONAL MOTORIZED RACK ADVANCE
DESCRIPTION
DATE
BY
9 SEPT 03
MJM
7OCT03 JAM
ELECTRIC HEAT MODELS
TB1
SP1
TO TB2-4
TO TB2-5
98
31
TO TB2-6
20
TO TB2-8
TO TB2-9
19
TO TB2
6
TO TB2-10
SEE NOTE 1
5
TO TB2-11
TO TB2-12
3A
TO TB2-15
15
SEE NOTE 2
2B
TO TB2-16
TO TB2-17
2A
TO TB2-18
14
SEE NOTE 2
TO TB3-10
SP2
TO TB3-11
97
TO TB3-12
70
TO TB3-13
32
30
TO TB3-14
TO TB3-15
29
22
TO TB3-16
17
TO TB3-18
TO TB3
16
SEE NOTE 1
TO TB3-19
10
TO TB3-20
SP3
TO TB3-22
4
3B
TO TB3-23
TO TB3-25
2C
GREEN
GND
TB1 RATED FOR 15A
GND
TB5
63
64
65
1. MAXIMUM INRUSH CURRENT 2.5 AMPS ON ANY ONE CONDUCTOR.
MAXIMUM CONSTANT CURRENT 1 AMP ON ANY ONE CONDUCTOR.
2. MAXIMUM ALLOWABLE CURRENT 1 AMP AT 120V.
3. JUMPER BETWEEN TB2-12 AND TB2-13.
4. JUMPER BETWEEN TB3-23 AND TB3-24.
5. AFTER ASSEMBLY CONNECT WIRE #21 BETWEEN TB2-7 AND TB3-17.
REV.
DESCRIPTION
TB2 AND TB3 LOCATED IN WIREWAYS ON FRONT OF TANKS
FROM DEVICE CONTACTORS
IN CONTROL CABINET
GND
3
3
3
SP
9
3
2
440
WASH TANK TERMINAL BLOCK -
SEE NOTE 3
FROM DEVICE CONTACTORS
IN CONTROL CABINET
3
3
3
3
4
4
5
5
5
SP
9
7
3
440
RINSE TANK TERMINAL BLOCK-
SEE NOTE 4
SEE NOTE 5
TB4 AND TB5 LOCATED IN JUNCTION BOXES FOR TANK HEATERS
63A
64A
60
10kW
65A
61
62
63B
64B
10kW
65B
RINSE TANK
63C
HEATERS
64C
10kW
65C
DATE
BY
The Dishwashing Machine Specialists
FROM TB1 IN
CONTROL CABINET
2
1
3
3
2
1
2
2
1
120
FROM TB1 IN
CONTROL CABINET
3
2
2
2
1
1
1
3
3
2
2
120
TB4
60A
61A
10kW
62A
WASH TANK
HEATERS
60B
GND
61B
10kW
62C
USN-72 ELECTRIC
WIRING INTERCONNECTIONS
B
REV.
701729
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

250-usn-72185-usn-72135-usn-7285-usn-7260-usn-72