Champion USN-72 Technical Manual page 149

High temperature two tank rack conveyor dishwasher with mran 90
Hide thumbs Also See for USN-72:
Table of Contents

Advertisement

120V CONTROLS
1
SW
OFF
ON
51
CB
3
3
START
TSK
2CR
1CR
STOP
4
5
6
8
1M
98
8
4
TSR
3CR
4
16
16A
TSB
16B
TSW
2CR
4
19
DSS
W
R
3A
21
22
3
3
FRSW
4
29
(IF USED)
TLS
3B
30
WFSW
3C
31
RFSW
3D
32
CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz,
REV.
AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION POINT
A
REVISED THERMOSTAT CONTACT LOGIC
MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.
B
REVISED SYMBOLS AND WIRE NUMBERS
DR.BY
J.NEWTON
SCALE
DATE
SHEET
1
OF
12JUNE00
1
2
3
SEE NOTE 1
SEE NOTE 2
3CR
MRA
MSW
5CR
1MOL
7
70
9
10
11
PRIME
4CR
8
97
15
4
17
18
20
SET FOR 5 SECONDS
3
6CR
23
CLUTCH
1
7
3
8
OFF DELAY
SET FOR 5 SECONDS
7CR
3
26
CLUTCH
1
7
3
8
OFF DELAY
DESCRIPTION
DATE
BY
13JULY00 JCN
23OCT03 JAM
PL
2A
DETERGENT
SIGNAL
2
IF USED
1M
2MOL
3MOL
4MOL
2
12
13
99
14
2M
2
3M
2
4M
2
98
TKL
15
2B
RINSE AID/
SANI SIGNAL
FRV
97
2C
2D
17
HC2
2F
18
BC1
20
2E
HC1
2
22
1CR
WT
2
2
4
2
M
6
25
2
2
5
2CR
RT
2
2
4
2
M
6
2
28
5
3CR
2
29
4CR
2
30
5CR
2
31
6CR
2
32
7CR
REV.
DESCRIPTION
DATE
TO CUSTOMER
DISCONNECT SWITCH
FUSED FOR 15A MAX. AT
440/60/3.
L1
L2
L3
GND
1MOL
L1
L2
L3
2MOL
L1
L2
L3
3MOL
L1
L2
L3
4MOL
L1
L2
L3
(IF USED)
L1
L3
FU1
FU2
P1
P2
440V
T1
120V
1
2
1CR
DOOR SAFETY SWITCH HOLD-IN RELAY
2CR
WASH TANK FLOAT HOLD-IN RELAY
3CR
RINSE TANK FLOAT HOLD-IN RELAY
4CR
FINAL RINSE SWITCH RELAY
5CR
TABLE LIMIT SWITCH RELAY
6CR
WASH TANK FLOAT SWITCH RELAY
7CR
RINSE TANK FLOAT SWITCH RELAY
1M
DRIVE CONTACTOR
1MOL
DRIVE MOTOR OVERLOAD
2M
WASH CONTACTOR
2MOL
WASH MOTOR OVERLOAD
3M
RINSE CONTACTOR
3MOL
RINSE MOTOR OVERLOAD
4M
MRA MOTOR CONTACTOR (IF USED)
4MOL
MRA MOTOR OVERLOAD (IF USED)
BC1
BOOSTER HEATER STEAM VALVE
CB
CIRCUIT BREAKER
DSS
DOOR SAFETY SWITCH
FRSW
FINAL RINSE SWITCH
FRV
FINAL RINSE VALVE
FU-
FUSE-TRASNSFORMER
NOTES
1. REMOVE JUMPER ACROSS WIRES 70
AND 9 WHEN RACK ADVANCE TABLE IS
USED.
2. REMOVE JUMPER ACROSS N.O. 5CR
CONTACT WHEN TABLE LIMIT SWITCH IS
USED.
BY
The Dishwashing Machine Specialists
1M
42
33
43
34
DRIVE
44
35
MOTOR
2M
45
36
46
37
WASH
MOTOR
47
38
3M
48
39
49
40
RINSE
50
41
MOTOR
4M
51
54
52
55
MRA
MOTOR
(IF USED)
53
56
HC1
WASH TANK HEAT STEAM VALVE
HC2
RINSE TANK HEAT STEAM VALVE
MRA
MRA MOTOR STOP SWITCH (IF USED)
MSW
MOTOR STOP SWITCH
PL
POWER ON LIGHT
RFSW
RINSE TANK FLOAT SWITCH
R
RINSE TANK DOOR SAFETY SWITCH
RT
RINSE TANK FLOAT TIMER
SW
POWER SWITCH
T1
440V:120V TRANSFORMER
TKL
LOW TEMP INDICATOR LIGHT
TLS
TABLE LIMIT SWITCH (IF USED)
TSB
BOOSTER THERMOSTAT
TSK
LOW TEMPERATURE CUT-OFF THERMOSTAT
TSR
RINSE TANK THERMOSTAT
TSW
WASH TANK THERMOSTAT
W
WASH TANK DOOR SAFETY SWITCH
WFSW
WASH TANK FLOAT SWITCH
WT
WASH TANK FLOAT TIMER
DIAGRAM STATE
POWER OFF
DOORS CLOSED
TANKS EMPTY
END OF CYCLE
USN-72
STEAM
701700
B
REV.
B