Full-height turnstiles with servo drive (40 pages)
Summary of Contents for Tiso SWEEPER-WP
Page 1
"TiSO-PRODUCTION" LTD WAIST-HIGH TURNSTILES SWEEPER-WP of swing lane of Speed Gate series OPERATION AND INSTALLATION MANUAL 2024 AUIA.206-20 rev.1.0.1 UKRAINE...
5.2 Turnstile transportation ............................33 6 DISPOSAL ..................................33 Annex А.Overall and installation dimensions of the “Sweeper-WP-1” and “Sweeper-WP-2” type turnstile ....34 Annex B. Control desk and connection diagram ....................... 35 Continued Annex B. Control panel and connection diagram .................... 36 Annex C.1.
Fig. 1 – Definition of the turnstile component description Turnstile " Sweeper-WP-1" - set of two single side cabinets Master and Slave: - identification order code T3.KCD.PD _/900 / 550 Turnstile "Sweeper-WP-2" - one double sided cabinet Master/Slave: - identification order code T3.KCD.PD. X / 550 / 900...
WARNINGS TO THE CUSTOMER ON SAFE OPERATION OF THE TURNSTILE These warnings are designed for ensuring of safety during operation of the turnstile to prevent violation of safety characteristics by improper installation or operation. These warnings are aimed at drawing attention of the customer to safety problems.
Width of set for one modification type width weight, kg Height (H) Length (L) lane (W) Sweeper-WP-1 550 1000 1260 Sweeper-WP-1 900 1316 * When the turnstile with more than two lanes is ordered: = 756 · s + 1106 · w + b total where s –...
Page 6
Dimensions, mm Max. Order code turnstile component weight, kg Height Width Length One side cabinet Master SWEEPER-WP-1.1 Т3.КСD.XD One side cabinet Slave SWEEPER-WP-1.2 1000 1260 Double side cabinet Master/Slave Sweeper-WP-2 Т3.КСD.XD.X Fig. 3 – Overall dimensions of the turnstile cabinet 1.1.4 The operation condition parameters according to GOST 15150-69 are specified in Table 3 For climatic...
1.3.1 The turnstile modification depends on the number of solid lanes: 1) For arrangement of single access way the turnstile "Sweeper-WP-1" is a set of two similar in design cabinets (Master and Slave) with one swing glass leaf (reference designation Т3.КСD.ХD);...
90° to either side depending on access direction. Each leaf is actuated by separate gear motor 13. Additional double sided cabinet "Sweeper-WP-2" is equipped with two gear motors 13 (one per each leaf), while cabinets of the turnstile "Sweeper-WP-1" have one gear motor for each cabinet.
Page 9
10 – swing glass leaf; 11 – shaft with leaf's holder; 12 – IR access sensors; 13 – gear motor. Fig. 4 – Design of single side cabinets type turnstile "Sweeper-WP-1" Т3.КСD.ХD Fig. 5 – Design of the "Sweeper-WP-2" type turnstile Т3.КСD.ХD.X...
Page 10
7 – leaf position sensor ; 12 – power supply unit; 8 – LED display (DotLights 13 – link board for Master and Slave; 14 - circuit breaker; Fig. 6 – General appearance and design of “Sweeper-WP-1” turnstile mechanism (Master cabinet)
Page 11
1.4.3 Principle of operation 1) Turnstile status indication - LED Light of card reader area; - LED lighting display showing access status; LED lighting of of glass partitions showing turnstile access status Fig.7 – Light indication of the turnstile status 2) Access cycle: Standby mode 1.
1.5 Description and operation of controlers as integral components of the turnstile 1.5.1 Turnstile controller AUIA.206.21.20.00 1.5.1.1 Appearance of controller AUIA.206.21.20.00 is shown in Figure 9. 1.5.1.2 Description of operation The controller provides algorithm of operation of the whole turnstile. It is assembled on the card from foil-clad textile laminate of 120 х...
Page 13
1 - ON - when command is generated the turnstile will be opened for 5 seconds; OFF - when command is generated the turnstile will be opened for the time set by ACS; 2 - ON- the state of outputs OUT1-5 will be NC; - OFF - the state of outputs OUT1-5 will be NO;...
Page 14
Table 5 Connector/ Signal parameters and Designation Direction Purpose Contact No description 1) logical «0» (0 2,2) V; INP1 ХТ4/1 ENTRY "TO BE OPENED FOR 2) logical «1» (3 5) V; ("TO BE OPENED A") SINGLE/FREE ACCESS" INP2 3) active level of signal ХТ4/2 ENTRY...
1.5.2 Motor controller АUIA.401.00.00-01 1.5.2.1. Description of motor controller АUIA.401.00.00-01 The controller АUIA.401.00.00-01 is designed to control BMDrive ® gear motors, which drives the turnstile leaves in motion. At each passage of turnstile installed pair of controllers АUIA.401.00.00-01: the first controller drive the leaf in the Master cabinet, the second controller drive leaf in the Slave cabinet.
Page 16
1.5.2.2. Description of the main page of the controller An OLED display and 4 control buttons are installed on the front side of the AUIA.401.00.00-01 controller for the displaying the current state of the controller and for configuration settings at menu After initialization of the controller the main page of the menu is displayed on the screen.
Page 17
№ Direction Designation Description Connector/contact XT1/1 EXIT Common wire of the control panel (GND ) XT1/2 DATA RS485 (1) communication line with 7-button TISO control XT1/3 DATA panel XT1/4 EXIT Power output for control panel (+12V) EXIT XT1/5 +12V Power output (+12V) for additional devices...
Page 18
Continued table 6 XP6/1 RS - A DATA RS 485 (2) communication line with the leaf position sensor XP6/2 RS - B DATA Сommon XP6/3 EXIT XP6/4 +12V EXIT Power supply of leaf position sensor XP8/1 ENTRY Jumper of line RS 485 (2) pull up resistor XP8/2 ENTRY Jumper of line RS 485 (2) termination resistor (load)
2 INTENDED USE 2.1 Operation restrictions 2.1.1 The turnstile must be used in the environment specified in p. 1.1.5 of this document subject to the specifications listed in section 1.2. 2.1.2 It is forbidden to use the turnstile: – at the presence of mechanical rattle in movable parts of the turnstile; –...
Page 20
2.2.5. Total configuration of the "Sweeper-WP" turnstile lanes Fig. 15 – The "Sweeper-WP" turnstile lanes arrangement options WARNING: The damages occurred during the turnstile transportation are not covered by the manufacturer's warranty liabilities...
Page 21
2.3. Installation procedure. The turnstile installation procedure is as follows: Damages to be fixed (picture to be taken, damage report to be made). The turnstiled to be unpacked and inspected for defects and damages as well as completeness to be checked according to the turnstile data sheet;...
Page 22
The relative position of cabinets and vertical position of the turnstile to be respected. Fig. 17 – Installation dimensions of the "Sweeper-WP-1" and "Sweeper-WP-2" turnstiles set The relevant holes to be drilled on the surface according to the marking due to diameter of anchors (12×120М10) for the turnstile fixation included in the scope of delivery.
Page 23
Fig. 18 – General view of connection between cabinets...
Page 24
Option 1 Option 2 Fig. 19 – Options of cable connection between cabinets Master and Slave...
Page 25
8. – The glass leaves to be installed on the glass holder shaft and adjust the zero position of the leaves(see further par.4.3) Fig. 20 - General view of the "Sweeper-WP-1" turnstile cabinet installation 12) Turnstile connection: a) Power supply cable ~230 V to be connected (Fig. 21): - Phase L to be connected to circuit breaker;...
Page 26
13) Installation of proximity card reader∗ upon availability of access control system (ACS) - The turnstile lid b (or glass top) to be removed by unscrewing screws а from frame (Fig.23); - Screws to be unscrewed and acrylite to be removed; - The maximum height of the card reader to be installed is 25 mm with specified permissible dimensions 110х80 - Acrylate to be fixed with screws in the previous position;...
2.4 Turnstile preparation for use 2.4.1 Commissioning guidelines Prior to the turnstile energization: 1) make sure of proper connection and good condition of all connecting cables; 2) clear the turnstile leaf swing area from foreign particles. When mains cable of power supply unit is connected to the network the turnstile operating mechanism is energized: leaves are locked from swinging in both directions barring access.
Continued Table 7 "LOCK" button to be Make sure that swing 9. Locked access in pushed to lock access in Red LED of locked access in one leaves are locked one direction chosen direction ("A" or chosen direction is lit "B")* Both "LOCK"...
3.3 Maintenance procedure 3.3.1 The turnstile maintenance includes preventive measures which are taken according to the established frequency to maintain the turnstile in operational condition, decreasing of component wearing and prevention of faults and malfunctions. 3.3.2 Daily and periodic maintenance of the turnstile are recommended. Normally the daily maintenance is carried out before the beginning of operation or during operational timeout and includes visual inspection of the turnstile's housing and, if required, troubleshooting of mechanical damages, surface corrosion and contamination.
4 ROUTINE MAINTENANCE 4.1 General guidelines Minor malfunctions of the turnstile are listed in Table 9 and to be remedied by the customer. More complicated malfunctions to be remedied by the manufacturer’s representative. IMPORTANT: INSPECTION, CLEANING, REPAIR OF THE TURNSTILE COMPONENTS TO BE PERFORMED ONLY AFTER THE TURNSTILE DEENERGIZATION! 4.2 Possible malfunctions Possible malfunctions of the turnstile and their remedies are listed in Table 9...
4.3. Adjustment of the zero position of leaf for “Sweeper-WP-1” For “Sweeper -WP” turnstiles, the zero position can be at point CLOSE (0). For turnstiles of this type, the zero position is set manually by the user during working area searching.
Page 32
Option ІІ (with АUIA.401.00.00-01 fig.25) Run the menu holding for 2 seconds the lower button (1) on the controller АUIA.401.00.00-01 and choose “Calibration”->”GateZeroSet” controller. If you request a calibration procedure, the turnstile will go to “OFF” mode. Set the zero point of both leaves of Master and Slave cabinets manually (CLOSE position (3)) ...
5 TRANSPORTATION AND STORAGE 5.1 Turnstile storage It is forbidden to subject the turnstile to jerks and impacts during storage. Transportation trolleys to be used for handling of the turnstile. In storage facilities there should not be aggressive gases and vapours causing metal corrosion. Air temperature during storage should not be below +5°...
Annex B. Control desk and connection diagram 1 – control panel body; 5 – "FREE ACCESS" mode control button 2 – "SINGLE ACCESS" mode control button 6 – "PANIC" mode control button 3 – front plate; 7 – access direction LED display; 4 –...
Annex C.1. Wiring diagram of the Sweeper-WP 1.1 BLDC Master (AUIA.206-20) Rev 0.6 MINI-FIT 8 Z5BLD120-24GUL ПВ3 0 .7 5 (Gre e n ) MOT B (V) Hall C (W) ПВ3 0 .7 5 (Ye l l o w ) MOT A (U) ПВ3 0 .7 5 (Bl u e )
Annex C.2.Wiring diagram of the Sweeper-WP 1.2 BLDC Slave (AUIA 206-20) Rev 0.6 MINI-FIT 8 Z5BLD120-24GUL ПВ3 0 .7 5 (Gre e n ) MOT B (V) Hall C (W) ПВ3 0 .7 5 (Ye l l o w ) MOT A (U) ПВ3 0 .7 5 (Bl u e )
Annex D.1. Diagram of the turnstile connection to access control system (ACS) Relay 1 Relay 2 Door contact 1 Door contact 2 inp1 - "TO BE OPENED A" in pulse mode. When command is issued entry is activated for 5 sec. inp2- "TO BE OPENED B"...
Annex D.2. Diagram of the turnstile connection to access control system (ACS) inp1- " TO BE OPENED A" in pulse mode. When command is issued the input is activated for 5 sec. . inp - 2 " TO BE OPENED B" in pulse mode. When command is issued the input is activated for 5 seconds.
Annex D.3 Diagram of the turnstile connection to fire alarm (FA) inp1- " TO BE OPENED A" in pulse mode. When command is issued the input is activated for 5 sec. inp - 2 " TO BE OPENED B" in pulse mode. When command is issued the input is activated for 5 seconds.
Manufacturer: LLC TiSO-PRODUCTION 14, Promyslova Street, Kyiv, 02088, Ukraine Phone: +38 (044) 291-21-11 Tel./fax: +38 (044) 291-21-02 E-mail: sales@tiso.global www.tiso.global SERVICE CENTER e-mail: service1@tiso.global Our equipment complies with requirements of the European Standards: EN ISO 12100:2010, EN ISO 14118:2018, EN 60204-1:2018, EN ISO...
Need help?
Do you have a question about the SWEEPER-WP and is the answer not in the manual?
Questions and answers