Enter the IP address of the device you wish to configure in a web browser. Enter the Installer PC Code of the panel
(same as the PC Password in BabyWare, default 0000).
From the web interface, once connected to the web page, disable Swan connection as shown below and disable
DHCP if needed. If DHCP is disabled and unable to connect with the device, reset to default will enable DHCP.
To configure reporting, enter panel programming via keypad or BabyWare (serial port). Enter the CMS account
number, IP address(es) of the receiver(s), Port, and security profiles (2-digit number), that indicates the supervision
time. Up to two receivers can be used to report with the IP150+MQ. If you are currently reporting to four receivers,
once you upgrade to an IP150+MQ, you will no longer be able to configure or report to four receivers.
After the reporting configuration is finalized (panel registered to an IPC10), a panel connection with BabyWare can be
established following one of the next procedures.
Option 1
To connect with BabyWare follow the below steps:
1.
Open the Account page and select the IPC server option.
2.
Enter the label of the IPC10 receiver, the IP of the IPC10, and the port (8883 default).
3.
Select the Scan Panel option and follow the messages on the screen.
4.
From the list of the IPC Server Group, you can now connect to the panel of your choice.