Paradox IP150+MQ Installation Manual page 7

Internet module

Advertisement

3)
Select the Areas and Event groups that generate email notifications.
NOTES:
-
Enter the username without the @domain.
-
Sending emails is not supported in closed networks (custom SMTP not supported).
Reporting to the IPC10 Receiver in closed networks (no internet)
Reporting in a closed network requires IPC10 V1.01.000 (and up), and BabyWare V5.6.40 (and up) for
connection/configuration. The below will be valid only if the Internet is not available on the connected network.
When IP150+MQ is connected to the network without internet access, it will enable web page access. With a PC
connected to the same local network of the IPC10 and the devices, use BabyWare, select Static IP connection type,
and use the scan feature to find the IP of the IP150+MQ modules. A list of Paradox IP devices will appear (IP150+,
IP150, and IP180 with supported versions) with their IP addresses and their serial numbers. Added the two pictures
below.
Page 7