Cache mode change from StorTrends Logs

set_cache_mode: Device index [0] name [/dev/mapper/c0_v0]
current mode [WB]
LOCAL ADDITION OF DEVICE TO CACHE
Device[/dev/mapper/c0_v0] added to cache
Device Index
: 0
Cache Mode
: Write Through
Reference Count : 1
The ManageTrends event log is also updated with this information the A/C power was
turned off.
The status of the UPS, whether it is running on A/C or battery and the amount of charge
and time remaining in the UPS can be monitored using the ManageTrends or the CLI, as
mentioned before. The following screenshot displays the state of ManageTrends and CLI
output when the UPS is running in battery mode.

UPS on Battery Mode

Monitoring UPS from CLI

[root@ITX003048841e04 ~]# cli get -i
Model
Smart-UPS 1000
Status
Battery Power
Load
63 %
Battery charge
83 %
Time left
013 min
Mode
Master/Single
Once any one of the condition specified for the graceful shutdown is met in the UPS, the
StorTrends boxes log this information, post an event to the ManageTrends event log and
trigger an automatic graceful shutdown of the boxes. This process ensures that all the
data in the Write-Back caches are flushed to disk before shutting off. Thus the StorTrends
boxes guarantee the reliable performance of the boxes without any data loss.
ups
Appendix H : UPS Configuration 247