SHOWTEC ACT Flood 200 RGBAL Quick Start Manual
SHOWTEC ACT Flood 200 RGBAL Quick Start Manual

SHOWTEC ACT Flood 200 RGBAL Quick Start Manual

Hide thumbs Also See for ACT Flood 200 RGBAL:

Advertisement

Quick Links

QUICK START GUIDE
ENGLISH
V1.0
ACT Flood 200 RGBAL
Product code: 34042
c
c
c

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACT Flood 200 RGBAL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SHOWTEC ACT Flood 200 RGBAL

  • Page 1 QUICK START GUIDE ENGLISH V1.0 ACT Flood 200 RGBAL Product code: 34042...
  • Page 2 ACT Flood 200 RGBAL Preface Thank you for purchasing this Showtec product. You can find the complete version of the user manual on our website www.highlite.com.                ©2024 Showtec. All rights reserved. No part of this document may be copied, published or otherwise reproduced without the prior written consent of Highlite International.
  • Page 3: Table Of Contents

    ACT Flood 200 RGBAL Table of contents 1. Introduction ............................
  • Page 4: Introduction

    You can find the latest version of the user manual on our website www.highlite.com. After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: • • Showtec ACT Flood 200 RGBAL • • Barndoor • •...
  • Page 5: Symbols And Signal Words

    ACT Flood 200 RGBAL 1.5. Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in death or DANGER serious injury.
  • Page 6: Safety

    ACT Flood 200 RGBAL Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. 2.1.
  • Page 7 ACT Flood 200 RGBAL WARNING Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights. Attention Power supply • • Before connecting the device to the power supply, make sure that the current, voltage and frequency match the input voltage, current and frequency specified on the information label on the device.
  • Page 8: Requirements For The User

    ACT Flood 200 RGBAL Attention Do not expose the device to conditions that exceed the rated IP class conditions. This device is IP20 rated. IP (Ingress Protection) 20 class provides protection against solid objects greater than 12 mm, such as fingers, and no protection against harmful ingress of water.
  • Page 9: Product Specifications

    Product Specifications The Showtec ACT Flood 200 RGBAL is a 200 W RGBAL LED flood light. It projects a bright, soft field of colored light and has a fixed beam angle of 90° x 105°. The color temperature can be adjusted between 2800 K and 10000 K.
  • Page 10: Installation

    ACT Flood 200 RGBAL Product Properties: Cooling Convection  Rigging: Mounting options Bracket / Floor  Thermal Specifications: Maximum Ambient Temperature 45 °C Included Items: Included cables Power Pro Cable  Included accessories Barndoor  Installation 4.1. Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property.
  • Page 11: Connecting To Power Supply

    Do not link more devices on one power link than the maximum recommended number. Maximum recommended number of devices: • • at 100–120 V: 5 devices ACT Flood 200 RGBAL • • at 200–240 V: 10 devices ACT Flood 200 RGBAL...
  • Page 12: Setup

    5.2. Stand-alone Setup When the ACT Flood 200 RGBAL is not connected to a controller or to other devices, it functions as a stand- alone device. It can be operated manually via the control panel and via the manual controls.
  • Page 13: Dmx Addressing

    04) Continue assigning the starting addresses of the remaining devices by adding each time 12 to the previous number. Make sure that you do not have any overlapping channels in order to control each ACT Flood 200 RGBAL correctly. If two or more devices are addressed similarly, they will work similarly.
  • Page 14: Operation

    ACT Flood 200 RGBAL Operation 6.1. Safety Instructions for Operation Attention This device must be used only for the purposes it is designed for. This device is intended for professional use as a flood light. It can be installed only indoors. This device is not suitable for households and for general lighting.
  • Page 15: Menu Overview

    ACT Flood 200 RGBAL 6.2. Menu Overview Level 1 Level 2 Level 3 Level 4 DMX Address 001–512 RAW – 5 Ch. Mode Basic – 8 Ch. Adv. – 12 Ch. DMX Functions Manual Defined DMX Fail Hold Blackout View DMX Value (Depends on the DMX channel mode)
  • Page 16: Dmx Channels

    ACT Flood 200 RGBAL 6.3. DMX Channels Basic Advanced Function Value Setting 5 CH 8 CH 12 CH 000–255 From low to high intensity (0–100 %) Green 000–255 From low to high intensity (0–100 %) Blue 000–255 From low to high intensity (0–100 %) Amber 000–255 From low to high intensity (0–100 %)
  • Page 17 ACT Flood 200 RGBAL Basic Advanced Function Value Setting 5 CH 8 CH 12 CH 169–172 Color 43 Liberty Green   173–176 Color 44 Lilac Tint   177–180 Color 45 Lee Fluorescent 4300 K   181–184 Color 46 No Color Blue  ...
  • Page 18 ACT Flood 200 RGBAL Basic Advanced Function Value Setting 5 CH 8 CH 12 CH 128–191 Color Fade 1–16 192–255 Color Change 1–16 000–255 Speed adjustment, from slow to fast (Built-in programs in Speed CH 11) Note: • • Make sure that the Strobe channel and the Master Dimmer channel are open in 8-CH and 12-CH mode in order to see the light output.
  • Page 19: Troubleshooting

    ACT Flood 200 RGBAL Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
  • Page 20: Maintenance

    ACT Flood 200 RGBAL Maintenance 8.1. Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. 8.2. Preventive Maintenance Attention Before each use, examine the device visually for any defects. Make sure that: •...
  • Page 21: Corrective Maintenance

    ACT Flood 200 RGBAL 8.3. Corrective Maintenance The device does not contain user-serviceable parts. Do not open the device and do not modify the device. Refer repairs and servicing to instructed or skilled persons. Contact your Highlite International dealer for more information.
  • Page 22: Disposal

    ACT Flood 200 RGBAL Disposal Correct disposal of this product Waste Electrical and Electronic Equipment This symbol on the product, its packaging or documents indicates that the product shall not be treated as household waste. Dispose of this product by handing it to the respective collection point for recycling of electrical and electronic equipment.
  • Page 23 ACT Flood 200 RGBAL Product code: 34042...
  • Page 24 Showtec is a brand of Highlite International B.V.

This manual is also suitable for:

34042

Table of Contents