Installation And Removal Of Exhaust Hose - Sharp CV-P10RC Installation And Operation Manual

Portable type
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION AND REMOVAL OF EXHAUST HOSE

The exhaust hose must be installed or removed in accordance with the usage mode.
MODE
COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container
DEHUMIDIFICATION with container(minimum capacity 3
Installation of the exhaust hose
1
Attach the window exhaust adapter to
the exhaust hose.
Extend one end of the exhaust hose
and insert it into the window exhaust
adapter, and turn it (approx. three times)
until it stops.
Make sure they are securely attached.
2
Attach the exhaust hose adapter to
the unit.
Insert the two projections on the ex-
haust hose adapter into the two holes
on the unit, and fi rmly attach them to
each other.
3
Slide and open the exhaust cover on
the window panel, and attach the win-
dow exhaust adapter.
Surface of window exhaust adapter
marked "TOP" should be at the top
when it is installed in a double-hung
sash window.
Surface of window exhaust adapter
marked "TOP" should be on the window
frame side when it is installed in a
sliding sash window.
The exhaust hose should be as short as possible for operational effi ciency;
however, it must not be twisted or bent.
Unacceptable
1 /
gallons)
2
Acceptable
E-14
EXHAUST HOSE
Install
Remove
Window ex-
haust adapter
Extend
Exhaust hose
Projection
Hole
Acceptable
"TOP"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents