TopPage CVP09LX SERVICE MANUAL S1651CVP09LX/ PORTABLE AIR CONDITIONER CV-P09LX MODELS CV-P10LC In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
CVP09LX CVP09LX Service Manual CHAPTER 1. PRODUCT SPECIFICATION [1] SPECIFICATION MODEL CV-P09LX CV-P10LC Cooling Capacity BTU/h 9000 9500 Moisture Removal Pint/h Electrical Data Phase Single Rated frequency Rated voltage Rated current Rated input 1010 Power factor BTU/Wh Compressor Type (Hermetically sealed rotary type)
CVP09LX [5] PART NAMES 1. Front view Air Outlet Vertical louvers Horizontal louvers PLASMACLUSTER Lamp (blue) Remote control signal receiver window POWER Button OPERATION Lamp (red) TIMER Lamp (orange) MEGA COOL Lamp (green) Air inlet 2. Rear view Exhaust air outlet Window exhaust adapter Exhaust hose Remote control hook...
Page 5
CVP09LX 3. Remote control Transmitter Display POWER Button LIGHTS Button TEMPERATURE Button PLASMACLUSTER Button 1 hr OFF Button MODE Button ON TIMER Button FAN Button OFF TIMER Button CANCEL Button LOUVERS Button RESET Button MEGA COOL Button 4. Remote control display MODE SYMBOLS : COOL : DEHUMIDIFICATION...
CVP09LX CVP09LX Service Manual CHAPTER 2. DISASSEMBLING PROCEDURE [1] PROCEDURE FOR DISASSEMBLY "ACTUAL UNITS MAY VARY SLIGHTLY FROM THOSE PICTURES BELOW" CAUTION: • DISCONNECT THE PORTABLE TYPE ROOM AIR CONDITIONER FROM THE POWER SUPPLY BEFORE ANY SERVICE. • DISCONNECT THE EXHAUST HOSE FROM THE UNIT BEFORE ANY SERVICE.(SEE OPERATION MANUAL “E-16”) •...
Page 7
CVP09LX 5. Push down the orifice (at position of illustration), as shown in below 7. Unscrew 6 screws holding the side panel L and R. figure, to unhook 2 hooks of front panel. Remove side panel L and R. 8. Remove the stopcock from the drainpipe nozzle. 6.
Page 8
CVP09LX 10.Remove the cabinet by lifting it up and pulling toward you as shown 13.Unscrew 2 screws holding the float switch ass’y. in below figure. Then move the float switch a little from bulkhead L. 11.Unscrew 4 screws holding the control box cover. 14.Unscrew 6 screws holding the bulkhead L.
Page 9
CVP09LX 15.Unscrew 7 screws holding the stay angle L. 19.Remove the plasmacluster unit and cluster cover. Remove the stay angle L. Disconnect the connector of plasmacluster unit. 20.Unscrew 5 screws holding the top duct Remove the top duct 16.Unscrew 3 screws holding the led guide. Remove the led guide.
Page 10
CVP09LX 22.Cut the fixing band holding the wires.(7 parts) 24.Cut the fixing band holding the wire and tape. Disconnect 8 connectors. Then remove the tape. CAUTION: CONNECT THE CONNECTORS OF FAN MOTOR ETC. CAUTION: KEEP THE TAPE IN CASE OF RE-ASSEMBLYING. CORRECTLY WHEN RE-ASSEMBLYING.
Page 11
CVP09LX 28.Unscrew 2 screws holding the control box. 31.Move the band to the direction shown in below figure (approx.11/ 16"). Remove the control box from the unit. Then removed the drain hose B. 32.Unscrew the screw holding the lead wire. 29.Unscrew 6 screws holding the casing cover.
Page 12
CVP09LX 34.Unscrew 4 screws holding the half plate. 36.Unscrew 6 screws holding the stay angle R. Remove the stay angle R from the unit. 37.Unscrew 3 screws holding the drain pump ass’y. Remove the drain pump ass’y from the unit. Then remove the half plate by lifting it up and pulling toward you as shown in below figure.
Page 13
CVP09LX 40.Unscrew 4 screws holding the motor cover and wire holder. Remove the motor cover. Then remove the fan motor. 41.Unscrew the screw holding the centrifugal fan. 42.Unscrew 5 screws holding the motor cover and wire holder. Remove the motor cover. Then remove the fan motor.
CVP09LX [2] DISASSEMBLING THE CONTROL BOX CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUNNING CAPACITOR BEFORE TOUCHING THESE CAPACITORS OR OTHER COMPONENTS OR WIRING. 1. Cut fixing bands holding the wires.(2 parts) 2. Remove 2 P.W.B. 3. Cut fixing bands holding the wires.(2 parts) Disconnect 6 connectors.
CVP09LX [3] FUNCTION Indoor fan speed Customer Setting 1. Cool Operation Evaporator Temperature AUTO In the "COOL" mode, the thermostat circuit is controlled by 3 thermo- Lower than D3 stat lines(C1~C3). Higher than D3 When the difference between Room Temperature and Preset Temper- 53.6 / 60.8°F ature is in [2]~[4] area, compressor is driving or starts driving.
Page 18
CVP09LX 7. Freeze preventive 9. POWER Button When the indoor pipe temperature falls below 32.0°F during cool oper- 9.1. Test Run ation or dry operation, the compressor is turned off. And if the indoor If the "POWER" button on the unit is pressed for 5 seconds or more pipe temperature rises exceeds 39.2°F after 3 minutes, the compres- during operation, cool test operation starts.
Page 19
CVP09LX 14. SELF-CHECK MODE Louver Louver (Upper Side) (Lower Side) YELLOW GREEN BLUE Room Temp Eva Temp Cond Temp Test Input 44.6~107.6°F 28.4~113.0°F 28.4~113.0°F P37 = H ~44.6°F, ~28.4°F, ~28.4°F, P37 = L 107.6°F~ 113.0°F~ 113.0°F~ Power On Start Function Select A Function Select B Select P44 = H...
CVP09LX [4] PERFORMANCE CURVES NOTE: 1) Use this data only as a guide to check the running condition. 2) The running conditions of this data is as follows. Remote control setting ..High cool, 64°F Drain pump ......OFF Exhaust hose ......Shortest 3) This data will be changed by operation conditions such as: a drain pump operation or an exhaust hose configuration.
CVP09LX CVP09LX Service Manual CHAPTER 4. ATTENTION WHEN REPAIRING [1] HOW TO REPAIR REFRIGERATION Before sealed system work can be preformed a refrigerant recovery EPA and LOCALLY approved certification is required, additionally, EPA and LOCALLY approved refrigerant recovery equipment is required. 1.
Page 22
CVP09LX 6. Heating the tubing Direct the torch flame so that the larger tube receives most of the heat. Silver solder flows at 1200°F and silfos flows at 1300°F. Heat all around the tubing. OUTER CONE The flame is composed of two cones, a smaller inner cone (pale blue) in calor and a much larger outer cone.
CVP09LX 8. Leaks Several methods are used to detect leaks in systems. • Electronic Leak Detectors are very sensitive and are able to detect leaks down to 1/2 ounce per year. A good electronic leak detector is generally far better in locating very small leaks. •...
CVP09LX CVP09LX Service Manual CHAPTER 5. TROUBLESHOOTING GUIDE [1] TROUBLESHOOTING No cooling Check the diagnostic program. Any LED does not turn on Refer to the page(4-4). Some LED turn on. Check the display& Neither fan nor louver works detector unit. Some fan or louver work.
Page 25
CVP09LX Check the LCDI (the power supply cord) Exhaust water from the lower outlet. All of them. Open the panels, and check the power cord output voltage. Check the voltage between white wire at R-capasitor under 100V and black wire at main relay(IN) on PWB. The voltage is under 100V Push the reset button on the LCDI.
Page 26
CVP09LX No cooling (Fan operate but the compressor doesn't operate.) under 100V Measure the power supply voltage at receptacle. Ask the power supply 120V(over 100V) company for check. insufficient Is it sufficient current capacity of power equipment ? Ask the power supply Is it small wiring for power company for check.
Page 27
CVP09LX No cooling (The compressor operate but the indoor fan motor doesn't operate) crack at the solder part disconnecting the connector Check CN3 on PWB ass'y Repair with over solder. Connect the connector properly. Check the indoor fan motor capacitor. (6μF) Change the indoor fan motor capacitor Measure the resistance...
Page 28
CVP09LX Operation stops immediately and a Should be performed drainage. TIMER, OPERATION, and MEGA (See step 6 and 7 "Whenever the unit is moved." COOL lamp blink. of page 2-7.) *CAUTION (Indicated of filled with water) It is possibility that the tank inside the unit has filled with condensation water.
Page 29
CVP09LX The compressor doesn't turn off. disconnecting Check the thermistor connector. Connect the connector properly. Checking method for the compressor relay. (RY1 and PWB) Check the thermistor resistance. Turn off the power Change the thermistor. supply. Measure the contact short Check the compressor resistance.
Page 30
CVP09LX Excessive vibration or Abnormal noise Excessive vibration or Abnormal noise in fan mode dirty Check the air filter not dirty Clean the air filter. Check rotating, direction of centrifugal fan.(to clockwise) Check the fan motor connector. Connect properly. Measure the resistance of fan motor coil.
CV-P10LC (Outside parts) “HOW TO ORDER REPLACEMENT PARTS” To have your order filled promptly and correctly, please furnish the For U.S.A. only following information. Contact your nearest SHARP Parts Distributor to order. 1. MODEL NUMBER 2. REF. No. 3. PART NO. 4. DESCRIPTION For location of SHARP Parts Distributor, Please call Toll-Free;...
Page 35
CVP09LX PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [2] CV-P09LX (Inside parts) Base pan ass'y CCHS-A914JBKZ Base pan ass'y DCHS-A536JBTA 1-10 Caster NKOM-A001JBEZ 1-11 PGUM-A164JBEZ Motor cushion 1-12 PGUM-A165JBEZ Motor cushion B 1-13 PGUM-A166JBEZ Motor cushion C 1-14 CGUM-A001JBKZ...
Page 36
CVP09LX [3] CV-P09LX (Control box parts) 2-20 2-11 2-17 6-44 2-13 -(1) 2-12 6-42 6-45 2-16 6-43 1-28 2-10 2-15 6-44 * Control board unit (2-2) consists of three units. 2-2-(1) · The main control unit with Fuse (2-10). 2-2-(2) · The display & detector unit.
Page 43
CVP09LX PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [8] CV-P10LC (Inside parts) Base pan ass'y CCHS-A914JBKZ Base pan ass'y DCHS-A536JBTA 1-10 Caster NKOM-A001JBEZ 1-11 PGUM-A164JBEZ Motor cushion 1-12 PGUM-A165JBEZ Motor cushion B 1-13 PGUM-A166JBEZ Motor cushion C 1-14 CGUM-A001JBKZ Drain plug 1-15 PSEL-C875JBEZ...
CVP09LX [9] CV-P10LC (Control box parts) 2-20 2-11 2-17 6-44 2-13 -(1) 2-12 6-42 6-45 2-16 6-43 1-28 2-10 2-15 6-44 * Control board unit (2-2) consists of three units. 2-2-(1) · The main control unit with Fuse (2-10). 2-2-(2) · The display & detector unit. 6-43 2-2-(3) ·...