Sharp CV-P09FR Installation And Operation Manual

Sharp CV-P09FR Installation And Operation Manual

Portable type room air conditioner
Hide thumbs Also See for CV-P09FR:

Advertisement

Quick Links

• Uses ozone layer friendly refridgerant R410A.
• Verwendet das die Ozonschicht schonende
Kühlmittel R410A.
• Utilise un réfrigérant qui n'attaque pas la couche
d'ozone, le R410A.
• Utilizza il refrigerante R410A che non danneggia
lo strato d'ozono.
• Utiliza refrigerante R410A que no daña la capa
de ozono.
• Gebruikt de ozon-vriendelijke koelvloeistof
R410A.
* Plasmacluster is a trademark of SHARP
Corporation.
R
PORTABLE TYPE
ROOM AIR CONDITIONER
INSTALLATION AND
OPERATION MANUAL
ENGLISH
PORTABLES
RAUMKLIMAGERÄT
INSTALLATIONS- UND
BEDIENUNGSHANDBUCH
CLIMATISEUR MOBILE
MANUEL D'INSTALLATION ET
D'UTILISATION
CONDIZIONATORE D'ARIA
TIPO PORTATILE
MANUALE PER L'INSTALLAZIONE
E IL FUNZIONAMENTO
ENGLISH
ACONDICIONADOR DE AIRE DE
HABITACIÓN TIPO PORTÁTIL
MANUAL DE INSTALACIÓN
Y FUNCIONAMIENTO
DRAAGBAAR TYPE
KAMER-AIRCONDITIONER
INSTALLATIE- EN
GEBRUIKSAANWIJZING
CV - P09FR

Advertisement

Table of Contents
loading

Summary of Contents for Sharp CV-P09FR

  • Page 1 MANUEL D’INSTALLATION ET D’UTILISATION CONDIZIONATORE D’ARIA TIPO PORTATILE MANUALE PER L’INSTALLAZIONE E IL FUNZIONAMENTO ENGLISH ACONDICIONADOR DE AIRE DE HABITACIÓN TIPO PORTÁTIL MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO DRAAGBAAR TYPE KAMER-AIRCONDITIONER INSTALLATIE- EN * Plasmacluster is a trademark of SHARP Corporation. GEBRUIKSAANWIJZING...
  • Page 2 If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling.
  • Page 3: Table Of Contents

    ENGLISH This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS • IMPORTANT SAFETY INSTRUCTIONS ... E-1 •...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS USAGE CAUTIONS • Ventilate the room periodically during use, especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before performing any maintenance or cleaning. • Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage.
  • Page 5: Location

    ENERGY EFFICIENCY TIPS • Avoid direct sunlight. Close blinds, drapes or shades to keep out direct sunlight while in cooling mode. • Keep the filter clean. Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air conditioner work harder and less effi- ciently.
  • Page 6: Part Names

    PART NAMES FRONT VIEW 1 Air Outlet 2 Vertical louvers 3 Horizontal louvers 4 PLASMACLUSTER Lamp (blue) 5 Remote control signal receiver window 6 AUX. Button 7 OPERATION Lamp (red 8 TIMER Lamp (orange 9 TURBO COOL Lamp (green 0 Air inlet REAR VIEW q Exhaust air outlet w Exhaust adapter...
  • Page 7 REMOTE CONTROL 1 Transmitter 2 Display 3 ON/OFF Button 4 DISPLAY Button 5 TEMPERATURE Button 6 PLASMACLUSTER Button 7 1 hr OFF Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER Button w CANCEL Button e SWING Button r RESET Button t TURBO COOL Button...
  • Page 8: Using The Remote Control

    USING THE REMOTE CONTROL LOADING BATTERIES Use two AAA (R03) batteries. Remove the battery cover at the back of the remote control. Insert batteries into the com- ± ± partment, making sure the ± ± ± and — — — —...
  • Page 9 HOW TO USE THE REMOTE CONTROL Point the remote control towards the units signal receiver window and press the desired button. A beep will sound when the unit receives the signal. • Make sure nothing, such as curtains, blocks the signal receiver window. •...
  • Page 10: Installation And Removal Of Exhaust Hose

    INSTALLATION AND REMOVAL OF EXHAUST HOSE The exhaust hose must be installed or removed in accordance with the usage mode. Mode Exhaust hose COOL, FAN, VENTILATION Install Projection DEHUMIDIFICATION Remove Exhaust adapter Hole Installation of the exhaust hose Attach the insect guard net to the ex- haust adapter.
  • Page 11: Cool Mode

    COOL MODE Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. Press the MODE button to select COOL mode. COOL DEHUM VENT Drainage nozzle “CLOSE position”...
  • Page 12: Dehumidification Mode

    DEHUMIDIFICATION MODE In this mode, the air conditioner dehumidifies the room. Remove the exhaust hose (See Page 8) Turn the drainage nozzle to the OPEN position. Drainage nozzle Pull the stopcock out from the drainage Stopcock nozzle. • When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.
  • Page 13: Fan Mode

    FAN MODE In this mode, the air conditioner simply circulates the air without cooling it. Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. Press the MODE button to select FAN mode.
  • Page 14: To Change Air Flow Direction

    TO CHANGE AIR FLOW DIRECTION UP/DOWN AIR FLOW DIRECTION Press the SWING button on the remote control. • The horizontal louvers will swing continuously. Press the SWING button again when the horizontal louvers are at the desired po- sition. • The horizontal louvers will stop moving. •...
  • Page 15: Turbo Cool Operation

    TURBO COOL OPERATION In this operation, the air conditioner fan works at extra high speed with a setting temperature of 15°C. Press the TURBO COOL button during cooling mode. • The remote control will display “ ” . • The temperature display will go off. •...
  • Page 16: Timer Operation

    TIMER OPERATION OFF TIMER The unit will turn off automatically according to your setting. Timer duration can be set from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Up to 9.5 hours, you can set in half-hour (30-minutes) increments and from 10 to 12 hours, in 1-hour increments.
  • Page 17 ON TIMER The unit will turn on automatically according to your setting. Timer duration can be set from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Up to 9.5 hours, you can set in half-hour (30-minute) increments and from 10 to 12 hours, in 1-hour increments.
  • Page 18: Plasmacluster Operation

    PLASMACLUSTER OPERATION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of posi- tive and negative ions released into the air will reduce some airborn mold. Press the PLASMACLUSTER button during operation.
  • Page 19: Drainage

    DRAINAGE Prepare for drainage and drain out water within the unit in the following cases. If the unit stops operating and the TIMER ( ), OPERATION ( ) and TURBO COOL ( lamps are blinking. (This indicates that the water tank inside the unit is full.) Make sure to turn the unit off.
  • Page 20: Maintenance

    MAINTENANCE Be sure to disconnect the power from the wall socket before performing any maintenance. CLEANING THE FILTERS If the filter is clogged with dust, the airflow will be reduced, resulting in poor cooling perform- ance. The filter should be cleaned every two weeks. REMOVE THE FILTERS •...
  • Page 21: Before Calling For Service

    BEFORE CALLING FOR SERVICE If the unit appears to be malfunctioning, check the following points before calling for a service. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Has the fuse blown or is the circuit breaker tripped? •...
  • Page 22 SHARP CORPORATION Osaka, Japan Printed in Thailand TINSEA419JBRZ 05AO...
  • Page 23 This file has been downloaded from: www.UsersManualGuide.com User Manual and User Guide for many equipments like mobile phones, photo cameras, monther board, monitors, software, tv, dvd, and othes.. Manual users, user manuals, user guide manual, owners manual, instruction manual, manual owner, manual owner's, manual guide, manual operation, operating manual, user's manual, operating instructions, manual operators, manual operator, manual product, documentation manual, user maintenance, brochure, user reference, pdf manual Downloaded from:...