CONTENTS 01/ Safety Instructions ....................2 02/ Technical Specifications ..................4 03/ Control Panel ......................6 04/ Fixture Installation ....................7 05/ How To Set The Unit .................... 11 5.1 Main Functions ....................11 5.2 Home Position Adjustment ................. 21 06/ Control By Universal DMX Controller ..............
01/ Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty.
Page 4
off the mains power immediately. DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly. DO NOT touch any wire during operation as there might be a hazard of electric shock. Avoid entanglement of the power cord with other wires. ...
02/ Technical Specifications Power Voltage 100-240V~ 50/60Hz Power Consumption 395W Light Source 576x0.8W RGBW LED Beam Angle 110° Field Angle 150° Dimmer/Strobe 0-100% smooth dimming; High output strobe effect 6+/11+/12+/13A+/13B+/17+/ DMX Channel 21A+/21B+/29+/37+/41+/53+ Channel DMX512 Control Control Mode Art-Net sACN Firmware Upgrade Firmware Upgrade via DMX link Display...
03/ Control Panel 1. Display To show the various menus and the selected function MENU To enter into move backward or leave the menu UP To go backward to move up in the menu 2. Buttons DOWN To go forward to move down in the menu ENTER To perform the desired functions For DMX512 link, use 5-pin XLR cable to link the unit and DMX...
04/ Fixture Installation IPX4 RATED An IP rated lighting fixture is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as “IP”...
Page 9
DO install and operate by qualified operator. Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas were unauthorized personnel might reach the fixture by hand. NEVER stand directly below the fixture(s) when rigging, removing or servicing.
Page 10
Splicing two fixtures: Installing the big hanging bracket (optional): - 9 -...
05/ How To Set The Unit 5.1 Main Functions To access the control menus, press the [MENU] button. Navigate the menu structure, using the [ENTER], [ UP] and [ DOWN] buttons. To select a menu option or to confirm a selection, press the [ENTER] button. ...
Page 13
MENU SUBMENU OPTIONS Blackout No DMX Status Hold Manual IP Address xxx.xxx.xxx.xxx Network Subnet Mask xxx.xxx.xxx.xxx 1. xxx.xxx.xxx.xxx Art-Net Setting 2. xxx.xxx.xxx.xxx 1. xxx… Universe: Add Pixel Setting sACN Setting 2. xxx… sACN Priority 0-200 Pixel Number Auto Network Option Art-Net sACN Linear...
Page 14
MENU SUBMENU OPTIONS Display Invert °C Temperature Unit °F Display Settings Display Warning English Fixture Language Chinese Auto Test 0-255 Green 0-255 Blue 0-255 Manual Test White 0-255 Intensity 0-255 Duration 0-255 Rate 0-255 Fixture Use Hour Total LED Hour LED Use Hour LED On Hour LED Hours Reset...
Page 15
DMX Settings Enter the control menu and select DMX Settings, press ENTER. Use the UP/DOWN button to select DMX Address, Channel Mode, No DMX Status, Network, Pixel Setting or Network Option. DMX Address Select DMX Address, press ENTER. Use UP/DOWN button to select an address, confirm your selection with ENTER.
Page 16
No DMX Status Select No DMX Status, press ENTER. Use UP/DOWN button to select one of the following status: Blackout (Fixture blacks out if DMX signal stops) Hold (The device continues to operate in the current mode with the last active DMX values until the signal returns) Manual (The device accepts the DMX value stored in the ‘Manual Test’...
Page 17
Fixture Settings Enter the control menu and select Fixture Settings, press ENTER. Use the UP/DOWN button to select Dimmer Curve, Dimmer Speed or White Balance. Dimmer Curve Select Dimmer Curve, press ENTER. Use UP/DOWN button to select Linear, Square Law, Inv SQ Law or S Curve, confirm your selection with ENTER.
Page 18
Display Settings Enter the control menu and select Display Settings, press ENTER. Use the UP/DOWN button to select Display Invert, Temperature Unit, Display Warning or Fixture Language. Display Invert Select Display Invert, press ENTER. Use UP/DOWN button to select Off (display normal) or On (display inverted), confirm your selection with ENTER.
Page 19
Manual Test Select Manual Test, press ENTER. Use UP/DOWN button to select the channel for which the manual test is to be performed, confirm your selection with ENTER. Use UP/DOWN button to select a value, confirm your selection with ENTER. To exit the menu, press MENU, or wait 30 seconds.
Page 20
Temperature Select Temperature, press ENTER. The device temperature is displayed. To exit the menu, press MENU, or wait 30 seconds. Firmware Version Select Firmware Version, press ENTER. The firmware version is displayed. To exit the menu, press MENU, or wait 30 seconds. RDM UID Select RDM UID, press ENTER.
Page 21
RDM functions: Certain menus of the device and functions can be called up via the RDM protocol. The parameter IDs are implemented as follows for different commands: Command Command Command Parameter ID ‘Discovery’ ‘Set’ ‘Get’ DISC_UNIQUE_BRANCH √ DISC_MUTE √ DISC_UN_MUTE √...
5.2 Home Position Adjustment To access the control menus, press the [MENU] button. To access the offset menus, long-press the [ENTER] button. Navigate the offset menus, using the [ENTER], [ UP] and [ DOWN] buttons. To select a menu option or to confirm a selection, press the [ENTER] button. ...
Page 23
Blue 1 Select Blue 1, press ENTER. Use UP/DOWN button to select a value between 0 and 255, confirm your selection with ENTER. To exit the offset menu, press MENU, or wait 30 seconds. White 1 Select White 1, press ENTER. Use UP/DOWN button to select a value between 0 and 255, confirm your selection with ENTER.
Page 24
White 2 Select White 2, press ENTER. Use UP/DOWN button to select a value between 0 and 255, confirm your selection with ENTER. To exit the offset menu, press MENU, or wait 30 seconds. Red 3 Select Red 3, press ENTER. Use UP/DOWN button to select a value between 0 and 255, confirm your selection with ENTER.
06/ Control By Universal DMX Controller 6.1 DMX512 Connection 1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
6.2 Address Setting If you use a universal DMX controller to control the units, you have to set DMX address between 1 and 512 so that the units can receive DMX signal. Press the MENU button to access the control menus, select DMX Settings, press the ENTER button to confirm.
6.3 DMX512 Configuration Please control the fixture by referring to the configurations below. Attentions: The unit will maintain the last condition until reset if you cut-off the DMX signal. For the channel Function, keep the value for about 3 seconds, then the ...
Page 28
DIMMER 0%100% 000-255 000-255 DIMMER FINE CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 12+ Channel (Mode 3): CHANNEL VALUE FUNCTION 000-255 0%100% GREEN 000-255 0%100% BLUE 000-255 0%100% WHITE 000-255 0%100% COLOR MACRO 000-008 Null 009-014 Color 1 015-021...
Page 29
183-189 Color 26 190-196 Color 27 197-203 Color 28 204-210 Color 29 211-217 Color 30 218-224 Color 31 225-231 Color 32 232-235 Color 1-32: Slow 236-239 Color 1-32: Medium 240-243 Color 1-32: Fast 244-247 Random Color: Slow 248-251 Random Color: Medium 252-255 Random Color: Fast CTO (8000K-2500K)
Page 32
STROBE DURATION 0%100% 000-255 STROBE RATE 000-005 Blackout 006-255 Strobe from Slow to Fast STROBE EFFECT 000-005 Null 006-050 Ramp up 051-100 Ramp down 101-150 Ramp up-down 151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 13B+ Channel (Mode 5): CHANNEL...
Page 33
006-050 Ramp up 051-100 Ramp down 101-150 Ramp up-down 151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 17+ Channel (Mode 6): CHANNEL VALUE FUNCTION RED 1 000-255 0%100% GREEN 1 000-255 0%100% BLUE 1 000-255 0%100%...
Page 34
000-005 Null 006-050 Ramp up 051-100 Ramp down 101-150 Ramp up-down 151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 21A+ Channel (Mode 7): CHANNEL VALUE FUNCTION RED 1 000-255 0%100% GREEN 1 000-255 0%100% BLUE 1...
Page 35
000-255 0%100% DIMMER 000-255 0%100% STROBE DURATION 0%100% 000-255 STROBE RATE 000-005 Blackout 006-255 Strobe from Slow to Fast STROBE EFFECT 000-005 Null 006-050 Ramp up 051-100 Ramp down 101-150 Ramp up-down 151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 21B+ Channel (Mode 8):...
Page 36
WHITE 3 0%100% 000-255 RED 4 000-255 0%100% GREEN 4 000-255 0%100% BLUE 4 0%100% 000-255 WHITE 4 000-255 0%100% DIMMER 000-255 0%100% STROBE DURATION 000-255 0%100% STROBE RATE 000-005 Blackout 006-255 Strobe from Slow to Fast STROBE EFFECT 000-005 Null 006-050 Ramp up...
Page 37
000-255 0%100% WHITE 2 000-255 0%100% RED 3 0%100% 000-255 GREEN 3 000-255 0%100% BLUE 3 000-255 0%100% WHITE 3 000-255 0%100% RED 4 000-255 0%100% GREEN 4 000-255 0%100% BLUE 4 000-255 0%100% WHITE 4 000-255 0%100% RED 5 000-255 0%100% GREEN 5...
Page 38
006-050 Ramp up 051-100 Ramp down 101-150 Ramp up-down 151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 37+ Channel (Mode 10): CHANNEL VALUE FUNCTION RED 1 000-255 0%100% GREEN 1 000-255 0%100% BLUE 1 000-255 0%100%...
Page 39
RED 5 0%100% 000-255 GREEN 5 000-255 0%100% BLUE 5 000-255 0%100% WHITE 5 0%100% 000-255 RED 6 000-255 0%100% GREEN 6 000-255 0%100% BLUE 6 000-255 0%100% WHITE 6 000-255 0%100% RED 7 000-255 0%100% GREEN 7 000-255 0%100% BLUE 7 000-255 0%100%...
Page 40
151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 41+ Channel (Mode 11): CHANNEL VALUE FUNCTION RED 1 000-255 0%100% GREEN 1 000-255 0%100% BLUE 1 000-255 0%100% WHITE 1 000-255 0%100% RED 2 000-255 0%100% GREEN 2...
Page 41
GREEN 5 0%100% 000-255 BLUE 5 000-255 0%100% WHITE 5 000-255 0%100% RED 6 0%100% 000-255 GREEN 6 000-255 0%100% BLUE 6 000-255 0%100% WHITE 6 000-255 0%100% RED 7 000-255 0%100% GREEN 7 000-255 0%100% BLUE 7 000-255 0%100% WHITE 7 000-255 0%100%...
Page 42
006-255 Strobe from Slow to Fast STROBE EFFECT 000-005 Null 006-050 Ramp up 051-100 Ramp down 101-150 Ramp up-down 151-199 Lightning 200-255 Random CONTROL MODE 000-127 Controlled by Art-Net / sACN 128-255 Controlled by DMX 53+ Channel (Mode 12): CHANNEL VALUE FUNCTION RED 1...
Page 43
BLUE 4 0%100% 000-255 WHITE 4 000-255 0%100% RED 5 000-255 0%100% GREEN 5 0%100% 000-255 BLUE 5 000-255 0%100% WHITE 5 000-255 0%100% RED 6 000-255 0%100% GREEN 6 000-255 0%100% BLUE 6 000-255 0%100% WHITE 6 000-255 0%100% RED 7 000-255 0%100%...
Page 44
RED 10 0%100% 000-255 GREEN 10 000-255 0%100% BLUE 10 000-255 0%100% WHITE 10 0%100% 000-255 RED 11 000-255 0%100% GREEN 11 000-255 0%100% BLUE 11 000-255 0%100% WHITE 11 000-255 0%100% RED 12 000-255 0%100% GREEN 12 000-255 0%100% BLUE 12 000-255 0%100%...
Page 46
36/144 ZONES: REGION ZONE CHANNEL VALUE FUNCTION 000-255 Red 0%100% 000-255 Green 0%100% Zone 1 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 2 000-255 Blue 0%100% White 0%100% 000-255 000-255 Red 0%100% Green 0%100% 000-255 Zone 3 Blue 0%100%...
Page 47
000-255 Red 0%100% 000-255 Green 0%100% Zone 8 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 9 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 10 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 48
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 16 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 17 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 18 Blue 0%100% 000-255...
Page 49
000-255 Red 0%100% 000-255 Green 0%100% Zone 23 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 24 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 25 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 50
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 31 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 32 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 33 Blue 0%100% 000-255...
Page 51
000-255 Red 0%100% 000-255 Green 0%100% Zone 38 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 39 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 40 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 52
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 46 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 47 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 48 Blue 0%100% 000-255...
Page 53
000-255 Red 0%100% 000-255 Green 0%100% Zone 53 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 54 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 55 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 54
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 61 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 62 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 63 Blue 0%100% 000-255...
Page 55
000-255 Red 0%100% 000-255 Green 0%100% Zone 68 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 69 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 70 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 56
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 76 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 77 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 78 Blue 0%100% 000-255...
Page 57
000-255 Red 0%100% 000-255 Green 0%100% Zone 83 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 84 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 85 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 58
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 91 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 92 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 93 Blue 0%100% 000-255...
Page 59
000-255 Red 0%100% 000-255 Green 0%100% Zone 98 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 99 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 100 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 60
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 106 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 107 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 108 Blue 0%100% 000-255...
Page 61
000-255 Red 0%100% 000-255 Green 0%100% Zone 113 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 114 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 115 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 62
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 121 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 122 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 123 Blue 0%100% 000-255...
Page 63
000-255 Red 0%100% 000-255 Green 0%100% Zone 128 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 129 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 130 000-255 Blue 0%100% White 0%100% 000-255 Red 0%100% 000-255...
Page 64
000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 136 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 137 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% Green 0%100% 000-255 Zone 138 Blue 0%100% 000-255...
Page 65
000-255 Red 0%100% 000-255 Green 0%100% Zone 143 000-255 Blue 0%100% 000-255 White 0%100% 000-255 Red 0%100% 000-255 Green 0%100% Zone 144 000-255 Blue 0%100% 000-255 White 0%100% LED PIXEL ZONES: - 64 -...
07/ Error Information Error codes are shown continuously in the display when the fixture fails and they will not disappear until the fixture is repaired. CPU-B Error Check whether the 485 (DATA) leads on the PCB board are installed in place or disconnected.
The position of each fan of the fixture: 08/ Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting: A. The unit does not work, no light and the fan does not work ...
09/ Fixture Cleaning It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke-fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment.
Page 71
Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2014/30/EU. EN 55032: 2015+A11: 2020; EN IEC 61000-3-2: 2019; EN 61000-3-3: 2013+A1: 2019; EN 55035: 2017. &...
Need help?
Do you have a question about the THUNDERBREAKER and is the answer not in the manual?
Questions and answers