1. Set the ventilation on the tank cover (2) to "ON".
2. Set the on/off switch (11) to the "RUN" position.
Note: The energy saving switch (10) must be set to "OFF".
When the engine is cold
1. Attention! Never allow the pull starter (5) to whip back. This can
result in damage.
2. Set the on/off switch (11) to the "CHOKE" position.
3. Now pull the pull starter (5) and the engine should start. If the engine
does not start, repeat the process.
4. Move the on/off switch (11) from the "CHOKE" position to the "RUN"
position after starting the engine (after approx. 15-30 seconds). (Fig.
6)
5. If the engine does not start even after several attempts, read the
"Troubleshooting" chapter.
Note:
If the engine is being started for the first time, several tries are required
to start until the fuel has been delivered from the tank to the engine.
Note: With high outside temperatures, it may be necessary to start the
power generator without the choke even when the engine is cold!
When the engine is warm
1. Set the on/off switch (11) to the "RUN" position.
2. Now pull the pull starter (5) quickly. The device should start after a
maximum of 2 pulls. If the device has still not started, repeat the pro-
cedure described under "Starting the engine when cold".
9.2 Shutting the engine off
Allow the power generator to run for a short time (approx. 30 seconds)
without load before switching it off so that it can "cool down".
1. Set the on/off switch (11) to the "OFF" position.
2. Disconnect the power consumers from the device.
3. Set the ventilation on the tank cover (2) to "OFF".