Input Selection - MULTISPAN MS-5716 User Manual

Advertisement

Parameters

Input Selection

Press
+
key.
SET
05
SCN
Press
key
SET
CH 1
Press
key
SET
CH16
Press
key
SET
j-ty
CH
1
Press
key
SET
j-ty
CH
16
Press
key
SET
Press
key to Save & Exit
ENT
Note :- Values can be changed
by pressing
Scan Time (Second)
/
Use
or
key to Skip or Unskip Channel
/
(Repeat the same procedure fpr all 16 channels)
To change the Input Type, Press
(J, K, PT-100, PT.1, 0-10V DC,
0-20mA DC & 4-20mA DC )
(Repeat the same procedure fpr all 16 channels)
or
keys.
Analog Range Selection
Press
Press
Press
Press
or
key
Press
Press
Note :- DP (Decimal Point) is Common for all channels.
Position can be changed by Pressing
Note :- Values can be changed
Press
+
key.
SET
Analog
SET
Set
key
SET
00.00
Decimal Point
DP
key
SET
00.00
Low Range Channel 1
LR-1
key
SET
00.00
(Repeat the same procedure fpr all 16 channels)
Lr16
key
SET
20.00
High Range Channel 1
Hr-1
key
SET
20.00
(Repeat the same procedure for all 16 channels)
Hr16
key
SET
Press
key to Save & Exit
ENT
by pressing
or
keys.
or
keys.