Figure 15: Disassembling the door station
Exchange module/insert
Door station is dismantled.
Pull off connection terminal block (12) on the
audio insert.
Remove the connection cables' connectors of
the module to be exchanged.
Loosen screws (20) of the module mounting at
the back (21) using a screwdriver and remove
the module mounting (Figure16).
Figure 16: Dismantling module mounting
(20) Screws
(21) Module mounting
Unlatch retaining brackets (22) of each module
by carefully lifting up with a screwdriver
(Figure 17).
5
Elcom Kommunikation GmbH - Gottfried-Leibniz-Str.1 - D-74172 Neckarsulm - www.elcom.de -
To remove the call push-button module, unlatch
the side retaining brackets (22) of the module
mounting by carefully lifting up with a screwdriv-
er (Figure 17).
(22)
(15)
Figure 17: Unlatching module
(22) Retaining brackets module mounting
After unlatching the module detaches itself from
the anchoring (22).
Remove the module to be replaced and install
the new module in reverse order.
i
Automatic or manual addressing of the module
is required to operate the door station.
Appendix
Technical data
Operating voltage
Current consumption audio insert
Stand-by
Current consumption audio insert
(21)
Operation
Current name plate lighting
per call push-button module
Menu
Backlighting On
setting
0
1
(20)
2
3
4
5
6
7
8
9
10
Table 3: Switch-on brightness level name plate-
lighting
Door release contact T/T potential-free
Door release unlocking time
Degree of protection
Degree of protection
Relative humidity
Operating temperature
Storage/transport temperature
Connecting terminals
for conductor diameter
22 ... 24 V=
5 mA
110 mA
45 mA
Backlighting Off
Permanent Off
≈ 750 lx
≈ 1600 lx
.
.
.
.
.
.
.
.
.
.
.
.
.
.
≈ 60 lx
≈ 110 lx
Permanent On
max. 24 V/1 A
1 ... 10 s
IP 44
IK07
0 ... 65 % (no condensation)
-20 °C ... +55 °C
-30 °C ... +80 °C
0.5 ... 0.8 mm
Dimensions:
Call push-button button small
Name plate small
Call push-button button medium
Name plate medium
Call push-button button large
Name plate large
Width of name plate insert
Surface compensation with flush-mounted
installation
Dimensions door station front (W x H x D):
with 0.5 or 1 module
with 0.5 and 1 module
133.5 x 295.8 x 2 mm
with 2 modules
with 0.5 and 2 modules
133.5 x 385.8 x 2 mm
with 3 modules
with 2 x 2 modules
with 3 and 2 modules or
with 2 x 3 modules
Accessories (extract)
Flush-mounted housing for door station:
with 0.5 or 1 module
with 0.5 and 1 module
with 2 modules
with 0.5 and 2 modules
with 3 modules
with 2 x 2 modules
with 3 and 2 modules or
with 2 x 3 modules
Surface-mounted housing for door station:
with 0.5 module or 1 module
with 0.5 module and 1 module
with 2 modules
with 0.5 and 2 modules
with 3 modules
with 2 x 2 modules
with 3 and 2 modules or
with 2 x 3 modules
Warranty
We reserve the right to realise technical and formal
changes to the product in the interest of technical
progress.
Our products are under guarantee within the scope
of the statutory provisions.
In case of service issues, please contact your
systems' engineer.
75.8 x 14.5 mm
72.1 x 12 mm
75.8 x 32.6 mm
72.1 x 30.1 mm
75.8 x 75.8 mm
72.1 x 66.3 mm
max. 0.5 mm
17 mm
133.5 x 242 x 2 mm
135 x 332 x 2 mm
133.5 x 422 x 2 mm
225.5 x 332 x 2 mm
225.5 x 422 x 2 mm
REW111Y
REW112Y
REW113Y
REW114Y
REW115Y
REW126Y
REW127Y
REW211Y
REW212Y
REW213Y
REW214Y
REW215Y
REW226Y
REW227Y