List of Setting Items

■ FUN Mode
This is the mode for setting the measurement conditions.
FUN Mode
SENSING
FILTER
OUTPUT
HOLD
0RESET
Settings
Default Value
MODE
STAND
SETTING
-
(*2)
LASER
AUTO
OBJECT
NORMAL
SYNC
OFF
GAIN
1
Measurement area
-
setting
(*1)
Measurement level
-
setting
(*1)
SMOOTH
ON
AVERAGE
128
DIFF
OFF
SCALING
OFF
TYPE
OFF
TRIGGER
EXT
DELAY
OFF
TYPE
REAL
OFFSET
0
Section 3
About Setup
Option/Setting Range
STAND, HI-RESO, HI-SPEED,
HI-SENS, CUSTOM (EXPOSE,
SKIP, LINE)
DIFFUSE, REGULAR
AUTO, RANGE, FIXED (upper limit
0.1 to 80%)
NORMAL, PCB, MIRROR, GLASS,
THICK, GAP
OFF, ON (timing A, timing B)
1 to 5
-
-
OFF, ON
1, 2, 4, 8, 16, 32, 64, 128,
256, 512, 1024, 2048, 4096
OFF, ON
OFF, ON (AUTO, MAN)
OFF, PEAK, BOTTOM, P-P,
AVERAGE, SAMPLE
EXT, SELF-UP, SELF-DN
OFF, ON (T-DELAY, T-TIME)
REAL, HOLD
-999.99 to 999.999
User's Manual
Pages
p.3-12
p.3-13
p.3-13
p.3-14
p.3-16
p.3-17
-
-
p.3-18
p.3-19
p.3-19
p.3-20
p.3-24
p.3-25
p.3-27
p.3-29
p.3-29
ZS-L
3-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs-ld20tZs-ld40tZs-ld50Zs-ld80Zs-ld200