Non-Measurement Settings - Omron ZS-L User Manual

Zs-l series smart sensor
Hide thumbs Also See for ZS-L:
Table of Contents

Advertisement

Section 4
Linear Input/Output
Setting
ONE
SHOT

Non-Measurement Settings

Set how the measurement values are to be output when a non-measurement state occurs
temporarily due to insufficient received light amount or the reset input state, for example.
Example: When the waveform skips due to insufficient received light amount
FUN mode -[I/O SET]-[NON-MEAS]
Setting
KEEP
CLAMP
(default
value)
In hold measurement, the output before the first hold value is obtained will be the same as [CLAMP]
even if [KEEP] is set.
ZS-L
4-6
User's Manual
When the judgment result changes to
PASS, outputs the PASS output for the
time set to the timer.
Neither the HIGH nor the LOW output
is output.
Range: 1 to 5000 (ms)
Amount of displacement
Direction of
workpiece
movement
When [KEEP] is selected
Amount of displacement
Judgment output
The status immediately before measurement is stopped is held and output.
All OFF
Outputs the set CLAMP value.
At current output : 4, 12 mA, 20 mA, MAX (approx. 25 mA, default value),
At voltage output : -10V, 0V, 10V, MAX (approx. 11 V, default value),
Description
Measured value
HIGH threshold value
LOW threshold value
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
State with waveform skip caused
by insufficient light amount
As the value before the skip occurred is kept,
this is effective in canceling waveform skip.
Outputs
Linear output
MIN (approx. 2 mA)
MIN (approx. -11 V)
: Timer time