Section 5
Measuring the Front Side of Black Sheet Rubber
RUN Mode
7.
Confirm the resolution with the workpiece in a
still state.
The minimum detectable resolution is displayed.
Refer to this as a reference as to whether or not the
resolution is at or below the required accuracy.
Generally speaking, moving the workpiece will impair the
resolution.
FUN Mode-[I/OSET]-[NO-MEAS]
8.
Select [CLAMP] to confirm whether or not the
workpiece can be measured if it is moved.
When measuring black or dark-colored workpieces hav-
ing a low reflection factor, the waveform sometimes jumps
due to light not returning to the light receiver section or
considerable differences in the amount of received light.
You can confirm whether or not there are jumps in the
waveform by displaying the waveform in a clamped state.
FUN Mode-[SYSTEM]-[SAVE]
9.
The save confirmation message is displayed.
Select [OK].
Save the settings to Sensor Controller internal mem-
ory.
RUN mode
10.
Check for jumps in the waveform by using the
graphic display on SmartMonitor ZS.
• When measuring black or dark-colored workpieces hav-
• If jumps are occurring in the waveform, select [KEEP].
ZS-L
5-4
User's Manual
Non-Measurement Settings p.4-6
ing a low reflection factor, the waveform sometimes
jumps due to light not returning to the light receiver sec-
tion or considerable differences in the amount of received
light. You can judge whether or not the measurement
state and sensing condition settings are acceptable by
displaying the waveform in a clamped state.
MAIN : MESURE
SUB : RESOLU
1
KEEP
2
CLAMP
Save the data ?
1
OK
2
CANCEL