Download Print this page

Omron ZFX-C-CD User Manual page 8

Smart sensor code reading functionality

Advertisement

MENU mode - [Setup] - [Item] - [Detail]- [Decode condition]
Setup Item
Code type
Timeout
Check digit
Composite component
Direction (Pharma)
Reverse (Pharma)
Possible output results
The following values can be output when expressions are set.
Item
Judgment result (JG)
Index (IN)
Num. of characters (N)
Characters
6
ZFX-C1_/C2_-CD Additional Functions Instructions
Setting Value
Description
JAN/EAN/UPC (default
Selects the type of barcode to be read.
value)
Code39
Codebar(NW-7)
ITF
Code 93
Code128, GS1-128
GS1 DataBar
Pharmacode
1 to 9999 ms (default
Sets the timeout time in read processing. A read error occurs if
value: 9999)
measurement does not end after the preset timeout time is
exceeded.
OFF
Selects whether or not to insert a check digit. This item is
enabled only when the following barcode types are selected:
ON (default value)
Codebar, Code39, ITF (Interleaved 2 of 5). When the other
codes are selected, this item is set to ON.
OFF (default value)
Sets whether or not to support composite codes.
This item is enabled only when the following barcode types are
ON
selected:
Code128/GS1-128, GS1-DataBar
Horizontal mode (default
Selects the reading direction. This item is enabled only when
value)
Pharmacode is selected as the barcode type.
Vertical mode
OFF (default value)
Sets whether or not to use the reverse mode. This item is
enabled only when Pharmacode is selected as the barcode
ON
type.
Description
The judgment result is output. (0: OK, -1: NG, -2: not measured)
Outputs the verification results (master model No.). (-2: verification results OFF or read
error, -1: verification results NG, 0 to 31: model No.)
Outputs the read number of characters. (0 to 1024)
Outputs the read text string.
Only codes that can be registered manually and 2-byte characters can be displayed as
text string in the result display screen. Other character codes (including control codes)
that are read are displayed as spaces. The read string is displayed up to 32 characters.
When more than 32 characters are read, "
···
" is displayed at the end of the string.

Advertisement

loading

This manual is also suitable for:

Zfx-cZfx-c1*-cdZfx-c2*-cd