Parallel Commands
The following commands were added:
Command
Description
AUTO setting
Automatically batch-sets all
measurement items.
Note
AUTO setting content differs with each measurement item.
ZFX User's Manual.
Serial Commands
According to the addition of measurement items, MEASDATA command and MEASPARA command
parameters were added.
MEASDATA command
Barcode, 2D Code
Data No.
Parameter
0
Judgment result
1
Index
2
Num. of characters
3
Characters
When text strings are output, the following control codes are converted before they are output.
When setting text strings, use the codes in the "After conversion" column.
Text code
Before conversion
Comma
&h2C
Tab
&h09
Space
&h20
CR
&h0D
LF
&h0A
Command code
DI7
DI6
DI5
1
1
1
For details, see "AUTO Setting" in Chapter 7 of the
Output Range
0 : OK
-1 : NG
-2 : not measured
0 to 31: Master data No. of verification
results
-2: Verification results OFF or read error
-1: Verification results NG
0 to 1024
Text string (0 to 1024 characters)
Character codes that cannot be displayed
(e.g. control codes) are displayed as
spaces.
After conversion
&h8540
&h8541
&h8542
&h8543
&h8544
ZFX-C1_/C2_-CD Additional Functions Instructions
Parameter (binary code)
DI4
DI3
DI2
DI1
DI0
*
*
*
*
*
15