Smart sensor code reading functionality

Advertisement

Decode condition detailed settings
Be Sure to set the detailed conditions for the code type. Set other items as required. By AUTO setting, Code
type, Mirror, Code color, Shape (Data Matrix) are set automatically.
MENU mode - [Setup] - [Item] - [Detail]- [Decode condition]
Setup Item
Setting Value
Code type
Data Matrix (EC200)
QR Code
MicroQR Code
PDF417
MicroPDF417
Maxi Code
AZtec Code
Codablock
Timeout
1 to 9999 ms
(default value: 9999)
Mirror
Normal (default value)
Reverse
Code color
Black
White
Black & White (default
value)
Shape (Data Matrix)
Square (default value)
Square & Rectangle
Possible output results
The following values can be output when expressions are set.
Item
Description
Judgment result (JG)
The judgment result is output. (0: OK, -1: NG, -2: not measured)
Index (IN)
Outputs the verification results (master model No.). (-2: verification results OFF or read
error, -1: verification results NG, 0 to 31: model No.)
Num. of characters (N)
Outputs the read number of characters. (0 to 1024)
Characters
Outputs the read text string.
Only codes that can be registered manually and 2-byte characters can be displayed as
text string in the result display screen. Other character codes (including control codes)
that are read are displayed as spaces. The read string is displayed up to 32 characters.
When more than 32 characters are read, "
Description
Selects the type of 2D Code to be read.
Sets the timeout time in read processing. A read error occurs if
measurement does not end after the preset timeout time is
exceeded.
Sets normal or reverse as the image orientation.
Specifies the code color.
This item is enabled only when the following barcode types are
selected:
Data Matrix, PDF417
Specifies the code shape.
This item is enabled only when the following barcode types are
selected:
Data Matrix
···
" is displayed at the end of the string.