Image adjustment (if necessary)
The following items can be changed and set to the image of the measurement target.
MENU mode - [Setup] - [Item] - [Img Adj]
Item
Select Camera
Color filter
Filtering
BGS level
Operation mode details (if necessary)
Set items below as required.
MENU mode - [Setup] - [Item] - [Detail] - [Function condition]
Setup Item
Verification func.
Verified master data
Partial verification
Compared digit
Output characters
Error string
Partial output
Output digit
Measurement control
4
ZFX-C1_/C2_-CD Additional Functions Instructions
Description
For details, refer to Chapter 3 "Image Adjustment" of the ZFX User's Manual.
Setting Value
OFF (default value)
ON
All master data (default
value)
Master data 0 to 31
OFF (default value)
ON
1 to 1024 (default value
first digit:1 last digit:1)
OFF (default value)
ON
Max. 20 digits (default
value: NG)
OFF (default value)
ON
1 to 1024 (default value
first digit:1 last digit:1)
OFF
ON (default value)
Description
When set to ON, verification with the master data is executed.
Selects the model to be used for verification.
The number of digits in the read results to be verified with the
master data can be limited. When [Partial verification] is set to
ON, set the first and last compared digit positions. Up to 32
characters can be set as the number of digits.
Example: First compared digit 2, last compared digit 6
O M R O N 2 0 0 8
6th digit
2nd digit
The text string used for verification becomes "MRON2".
Sets whether or not to output the read results on the serial
interface.
Sets the text string to be output when a read error occurs.
ASCII code table p.3
Sets whether or not to specify a range in the read data to output
from when [Output characters] is set to ON.
Sets the first and last digit positions to output. If the read text
string contains non-targeted digits, the error string is output.
Sets whether or not to control the next measurement item to be
executed based on the verification results.