Starting and Going Online from the CX-Programmer

3-2-1 Basic Window

3-2-2 Pop-up Menu

40
2. Select [Simulation] | [Simulator Online Connection] from the main menus.
The CX-Simulator will be started automatically for the PLC model specified
in the selected project and an online connect will be made unrelated to the
communications settings in the current project.
Note
If [Automatically Transfer Program to Simulator] was selected in the tool op-
tions, a dialog box for transferring the program to the CX-Simulator will appear
and the program will be transferred to the CX-Simulator when the [OK] button
is clicked.
If an online connection to the CX-Simulator is created from the
CX-Programmer, the following [Debug Console] window will be displayed for
the CX-Simulator.
Name
Title bar
Toolbar
Note
The main menus will not be displayed when an online connection to the
CX-Simulator has been created from the CX-Programmer.
The following pop-up menu will be displayed when the right mouse button is
clicked anywhere in the [Debug Console] window except on the title bar or on
an icon that can be selected.
When an online connection to the CX-Simulator has been created from the
CX-Programmer, this pop-up menu is used to select the following functions
instead of using the main menus.
The title is displayed along with the current cycle count.
The cycle count will be displayed in brackets [ ] when
the cycle has been paused.
Click an icon to select a function. Refer to 3-9 Debug
Console Window for details.
Section 3-2
Title Bar
Toolbar
Function