I/O Memory Allocation
Address
Words
Bits
A508
A50812 Trace
Completed
Flag
A50813 Trace Busy
Flag
A50814 Trace Start
Bit
A50815 Sampling
Start Bit
A509
A50900 SYSMAC
BUS Slave
Number
Refresh Bit
A510 to
Start-up
A511
Time
232
Name
ON when sampling of a region of
trace memory has been com-
pleted during execution of a
Trace.
OFF when the next time the
Sampling Start Bit (A50815) is
turned from OFF to ON.
ON when the Sampling Start Bit
(A50815) is turned from OFF to
ON. OFF when the trace is com-
pleted.
Turn this bit from OFF to ON to
establish the trigger condition.
The offset indicated by the delay
value (positive or negative) de-
termines which data samples are
valid.
When a data trace is started by
turning this bit from OFF to ON
from a Programming Device, the
PLC will begin storing data Trace
Memory by one of the three fol-
lowing methods:
1) Data is sampled at regular
intervals (10 to 2,550 ms).
2) Data is sampled when
TRSM(045) is executed in the
program.
3) Data is sampled at the end of
every cycle.
Turn this bit ON to refresh the
error information in A425 (unit
number of Slave where error
occurred after startup).
These words contain the time at
which the power was turned ON.
The contents are updated every
time that the power is turned ON.
The data is stored in BCD.
A51000 to A51007:
Second (00 to 59)
A51008 to A51015:
Minute (00 to 59)
A51100 to A51107:
Hour (00 to 23)
A51108 to A51115:
Day of month (01 to 31)
CS/CJ-series PLC
Function
CX-Simulator
Settings
Function
1: Trace
Same as
completed
CS/CJ-series
0: Not trac-
PLC.
ing or trace
in progress
1: Trace in
Same as
progress
CS/CJ-series
0: Not trac-
PLC.
ing (not
sampling)
1: Trace
Same as
trigger con-
CS/CJ-series
dition es-
PLC.
tablished
0: Not es-
tablished
0 to 1:
Same as
Starts data
CS/CJ-series
trace (sam-
PLC.
pling)
Not used.
See Func-
Same as
tion col-
CS/CJ-series
umn.
PLC.
Section 9-3