Section 10 Transferring Data
NS-Designer Operation Manual
2.
Click the Comms.Method Button at the top right of the dialog box. The Comms.Method Dialog
Box will appear.
3.
Select Pass Through PLC.
4.
Select the communications method under Computer. Here, Ethernet is set.
5.
Select the communications method between the PLC and PT. Here, CLK (Controller Link) is set.
Select this option to transfer through the PLC.
6.
Click the Set... Button to the right of the communications method setting. The following Network
Setting Dialog Box will appear.
7.
Input the Ethernet network address for the Network of the FINS source address. Here, 1 is set as
an example.
8.
Input network address and node number of the PLC's Ethernet Unit for the Network and Node of
the FINS destination address. Here the network address is set to 1 and the node number is set to
6 as examples.
9.
Click the Driver Tab and make the following settings.
Select the communications method
between the computer and PLC.
Select the communications method
between the PLC and PT.
10-51
10-3 Data Transfer Using SPMA
Set the Ethernet network
address
Set the network address and
node number of the PLC's
Ethernet Unit.
Input the response monitor time.
Increase the time only when there
are frequent communications
error.