Omron GRT1 - 27-11-2006 Operation Manual page 69

Profibus communication unit
Table of Contents

Advertisement

Setup the GRT1-PRT Configuration
Setting Parameters
Parameter Tab
Group Tab
Extension Tab
DPV1 Tab
!Caution In the Generic Slave DTM, DPV1 Tab, the DPV1 Enable check box is enabled
50
The figure below further illustrates the I/O Configuration selection.
Input Words
15
Word #1
Word #2
Word #3
Word #4
After selecting the I/O Configuration additional parameter settings can be
made in the other tabs. These tabs will not be shown here, as they are similar
to the settings explained in the previous section.
The Parameter Tab contains the setting for the FINS Fragment Length (See
FINS Fragment Length Setting on page 44).
The Group Tab allows setting of the Group selections (See Group Setting on
page 44).
The Extension Tab contains the Auto-CLEAR, Configuration Data Convention,
and the Error on Cyclic Data Exchange settings (See Auto-Clear Processing
on page 44, and further).
The DPV1 Tab contains settings related to DPV1.
by default. For the GRT1-PRT this must be disabled. The GRT1-PRT only
supports PROFIBUS DP-V1 Class 2 messages. If the flag has not been dis-
abled, I/O data exchange will not be achieved.
For more information on using the Generic Slave DTM, refer to the CS1/CJ1
PROFIBUS Master unit Operation Manual (W409).
Selected I/O
Modules
15
0
COM Status
GRT1-ID4
GRT1-ID4 *
GRT1-OD4
GRT1-ROS2 *
GRT1-ID4 *
GRT1-AD2 (I: Analog Input) Default
Section 3-3
Output Words
0
Word #1