Omron GRT1 - 27-11-2006 Operation Manual page 66

Profibus communication unit
Table of Contents

Advertisement

Setup the GRT1-PRT Configuration
Editing SmartSlice I/O Unit
Settings
1,2,3...
Using the On-Line
Functions
1,2,3...
Upload Button
Download Button
Compare Button
After making the I/O configuration selection, the settings of individual Smart-
Slice I/O Units can be set or changed. To do this, perform the following steps.
1. Select the SmartSlice I/O Unit in the I/O Configuration.
2. Press the Edit button below the I/O Configuration list. The appropriate set-
ting window will pop up (see for example below).
Note
1. In order to download/upload settings for individual SmartSlice I/O Units,
the DTM has to be on-line with the Physical GRT1-PRT Unit, i.e. it has to
be able to establish a connection with the device.
2. In the case of the GRT1-AD2 some parameter settings will affect the I/O
Configuration, i.e. it will change the I/O size for that particular SmartSlice
I/O Unit. In that case, the I/O Configuration for the PROFIBUS Master Units
needs to be (re-)downloaded. If this is required, an appropriate warning
window will pop up.
3. The configuration options and windows for individual SmartSlice I/O Units
are described in detail in GRT1 Series SmartSlice I/O Units Operation
Manual (W455)
At the bottom of the GRT1-PRT DTM are four buttons which will be Enabled
after the DTM has established communication with the physical device (via
the PROFIBUS Master Unit). Switching to on-line must be done via the FDT
Container. To switch to on-line, perform the following steps in Cx-Profibus.
1. In the Network view, select the GRT1-PRT and right-click the mouse.
2. From the context menu, which pops up, select the option Go Online.
The buttons functions are discussed below.
Pressing the Upload button will initiate an upload of all SmartSlice I/O Infor-
mation, i.e. I/O Configuration, Unit types and Unit parameters. From this
upload, the I/O Configuration in the Configuration list will be assembled.
Note Uploading may take some time, due to the amount of parameters.
Pressing the Download button will initiate a download of all SmartSlice I/O
Information, i.e. I/O Configuration, Unit types and Unit parameters.
Pressing the Compare button will initiate a comparison between the I/O Con-
figuration and parameters of all SmartSlice I/O Units and the data stored
Section 3-3
47

Advertisement