Installation; Terminal Arrangement - Omron G3PC Datasheet

Solid state relays with failure detection function
Table of Contents

Advertisement

Installation

■ External Specifications

Terminal Arrangement

Terminal name
Terminal number
Main circuit terminals
1/L1, 2/T1
(output)
Detection power sup-
3
ply terminal (input)
Operating circuit ter-
A1, A2
minals (input)
Alarm output termi-
X1, X2
nals (output)
Indicators
Name
Symbol
Status indicators
RDY
ALM
Input indicator
INPUT
Note: The same indicator is used as both the power supply indicator
and the alarm indicator.
■ Connection Example
(See note 1.)
Voltage output for Temperature
Controller, sequencer
12 to 24
VDC
Input for Temperature
Controller, sequencer
30 VDC
min.
(See note 2.)
Note: 1. If the detection power supply terminal (terminal 3) is not connected, failure detection is not performed and so be sure to connect this
terminal.
2. If the load is connected to terminal 1/L1, failure detection may not operate correctly and so connect the load to terminal 2/T1.
3. With inductive loads (relay coil, etc.), connect back-current prevention diodes to both sides of the load.
J-64
Solid State Relays with Failure Detection Function
Screw size
M4
M3.5
Color
Meaning
Green
SSR normal
Red
SSR failure detection
and circuit
disconnection
detection
Yellow
Operating
Display Labels
L1
1
3
A1
IN
A2
X1
ALM
X2
2
T1
Heater
Appearance
A1(IN
A2(IN )
X1(ALM
X2(ALM )
AC
G3PC
1/L1
3
RDY/ALM
+
INPUT
)
+
)
2/T1

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3pc-220b-vd

Table of Contents