G3RV
Slimmest OMRON plug-in SSR with
maximum width 6.2 mm
• Long electrical life and high speed switching
• Large plug-in terminals for reliable connection
• G3RV-D (DC load) models can manage resistive loads of
100 μA to 3.0 A
• LED indicator for visible operation checking
• Convenient quick electrical connections possible with G3RV
push-in models and cross bar connectors
• Low power consumption for energy savings
• G3RV is cUL listed when correct relay is matched with the
G3RV Socket
Model Number Structure
Model Number Legend
G3RV-SL
-
1
2
3
4
1. Basic Model Name
G3RV: Solid State Relay
2. Auxiliary Type Designation
SL: Slim Solid State Relay and socket combination
3. Wire Connection
700: Screw Terminals
500: Push-in (screwless) terminals
Ordering Information
List of Models
Classification
Plug-in terminals
General-purpose
SSR and Socket Combinations
Input voltage
12 VDC
G3RV-SL700-D 12VD
G3RV-SL700-A(L) 12VDC
24 VDC
G3RV-SL700-D 24VDC
G3RV-SL700-A(L) 24VDC
24 VAC/DC
G3RV-SL700-D 24VAC/DC
G3RV-SL700-A(L) 24 VAC/DC
48 VAC/DC
G3RV-SL700-D 48VAC/DC
G3RV-SL700-A(L) 48VAC/DC
110 VAC
G3RV-SL700-D 110 VAC
G3RV-SL700-A(L) 110 VAC
230 VAC
G3RV-SL700-D 230 VAC
G3RV-SL700-A(L) 230VAC
Enclosure rating
Unsealed
Screw terminals
G3RV-SL500-D 12VDC
G3RV-SL500-A(L) 12VDC
G3RV-SL500-D 24VDC
G3RV-SL500-A(L) 24VDC
G3RV-SL500-D 24VAC/DC
G3RV-SL500-A(L) 24VAC/DC
G3RV-SL500-D 48VAC/DC
G3RV-SL500-A(L) 48VAC/DC
G3RV-SL500-D 110VAC
G3RV-SL500-A(L) 110VAC
G3RV-SL500-D 230VAC
G3RV-SL500-A(L) 230VAC
4. Output voltage specifications
A(L): AC Output .. TRIAC
A: with Zero cross function AL: without Zero cross function
D: DC Output .. MOS FET
Input voltage
AC/DC
Screw term
Push-in terminals
Push-in terminals
Solid State Relays
Type of connection
Contact form
SPST
G3RV-SL700
G3RV-SL500
G3RV
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron G3RV-SL700-A Series

  • Page 1 Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm • Long electrical life and high speed switching • Large plug-in terminals for reliable connection • G3RV-D (DC load) models can manage resistive loads of 100 μA to 3.0 A •...
  • Page 2: Specifications

    Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input G3RV-SL700/500-A Series Rated voltage Rated current Must operate Must release Input voltage voltage voltage % of rated voltage 50 Hz 60 Hz ±10% 12 VDC 15 mA 10.8V 24 VDC 12 mA 21.6V 24 VAC/DC...
  • Page 3 ■ Characteristics Item G3RV-SL700/500-A G3RV-SL700/500-AL G3RV-SL700/500-D Operate time 1/2 of load power source cycle 1 ms max. 6 ms max. + 1 ms max. Release time 40 ms max. 20 ms max. 60 ms max. Output ON voltage drop 1.6 V rms max. 0.9 V max.
  • Page 4: Engineering Data

    Engineering Data ■ Load current derating curves G3RV-SL700/500-A(L) Series Mounting Distance 10mm Mounting Distance 0mm G3RV-SL700/500-D Series Mounting Distance 10mm Mounting Distance 0mm ■ One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) The values shown by the solid line are for non-repetitive inrush currents.
  • Page 5: List Of Models

    Accessories ■ PLC Interface (for G2RV-SL700 & G3RV-SL700 series only) List of Models Model number Description Connection P2RVC-8-O-F PLC Output Interface for 8x Ribbon cable connector G2RV-SL700 & G3RV-SL700 series 10 Pole, IEC603/1 PNP - type Specifications Input Rated voltage 30 VAC/VDC max.
  • Page 6: Model Number Legend

    ■ SSR for Maintenance (Replacement SSRs) Model Number Legend G3RV-@ @ @ @ 1. Output voltage specifications DC Output AC Output 2. Rated Current AC Output 2A DC Output 3A 3. Terminals Plug-In 4. Zero cross function Blank: with Zero cross function without Zero cross function List of Models Isolation...
  • Page 7: Specification

    ■ Cross bars Model Number Legend P2RVM -@ @ 1. Number of Poles 2. Color 020: 2 poles R: Red 030: 3 poles S: Blue 040: 4 poles B: Black 100: 10 poles 200: 20 poles List of Models Model number Poles Quantity Color...
  • Page 8: Complete Unit

    ■ Separating Plates Model number Quantity Description P2RV-S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation. Dimensions Note: All units are in millimeters unless otherwise indicated. Complete Unit G3RV-SL700 Input circuit 106.7 max. 70.9 47.2 6.2 max. 26.1 24 V DC Other Input Voltage...
  • Page 9: Input Circuit

    G3RV-SL500 Input circuit 106.7 max. 82.9 69.8 6.2 max. 24.6 24 V DC Other Input Voltage Terminal Arrangement/ Terminal Arrangement/ Internal Connections Internal Connections 97.4 max. (Top View) (Top View) 88.9 99.2 12 V DC Terminal Arrangement/ Internal Connections (Top View) Solid State Relay G3RV-D03SL Input circuit...
  • Page 10: Installation

    Installation ■ Tools G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. Applicable Screwdriver ● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) ●...
  • Page 11 ■ Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a G3RV-SL500 series. G3RV-SL700 7 mm G3RV-SL500 12 mm Fig. 1 Exposed Conductor Length Wiring Procedure for G3RV-SL500 series Screwdriver hole Wire connection hole...
  • Page 12: Precautions For Connection

    Precautions Precautions for Connection • If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. • Do not move the screwdriver up, down, or from side to side while it •...
  • Page 13: Definition Of Precautionary Information

    ● Handling Definition of Precautionary Information • Be sure to provide adequate air flow to G3RV. Failure to do so can cause the G3RV to overheat leading to short circuit and Indicates a potentially hazardous situation which, burning. if not avoided, will result in minor or moderate WARNING injury, or may result in serious injury or death.
  • Page 14: Suitability For Use

    Suitability for Use OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the product.