Page 1
Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm • Long electrical life and high speed switching • Large plug-in terminals for reliable connection • G3RV-D (DC load) models can manage resistive loads of 100 μA to 3.0 A •...
Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input G3RV-SL700/500-A Series Rated voltage Rated current Must operate Must release Input voltage voltage voltage % of rated voltage 50 Hz 60 Hz ±10% 12 VDC 15 mA 10.8V 24 VDC 12 mA 21.6V 24 VAC/DC...
Page 3
■ Characteristics Item G3RV-SL700/500-A G3RV-SL700/500-AL G3RV-SL700/500-D Operate time 1/2 of load power source cycle 1 ms max. 6 ms max. + 1 ms max. Release time 40 ms max. 20 ms max. 60 ms max. Output ON voltage drop 1.6 V rms max. 0.9 V max.
Engineering Data ■ Load current derating curves G3RV-SL700/500-A(L) Series Mounting Distance 10mm Mounting Distance 0mm G3RV-SL700/500-D Series Mounting Distance 10mm Mounting Distance 0mm ■ One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) The values shown by the solid line are for non-repetitive inrush currents.
Accessories ■ PLC Interface (for G2RV-SL700 & G3RV-SL700 series only) List of Models Model number Description Connection P2RVC-8-O-F PLC Output Interface for 8x Ribbon cable connector G2RV-SL700 & G3RV-SL700 series 10 Pole, IEC603/1 PNP - type Specifications Input Rated voltage 30 VAC/VDC max.
■ SSR for Maintenance (Replacement SSRs) Model Number Legend G3RV-@ @ @ @ 1. Output voltage specifications DC Output AC Output 2. Rated Current AC Output 2A DC Output 3A 3. Terminals Plug-In 4. Zero cross function Blank: with Zero cross function without Zero cross function List of Models Isolation...
■ Cross bars Model Number Legend P2RVM -@ @ 1. Number of Poles 2. Color 020: 2 poles R: Red 030: 3 poles S: Blue 040: 4 poles B: Black 100: 10 poles 200: 20 poles List of Models Model number Poles Quantity Color...
■ Separating Plates Model number Quantity Description P2RV-S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation. Dimensions Note: All units are in millimeters unless otherwise indicated. Complete Unit G3RV-SL700 Input circuit 106.7 max. 70.9 47.2 6.2 max. 26.1 24 V DC Other Input Voltage...
Installation ■ Tools G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. Applicable Screwdriver ● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) ●...
Page 11
■ Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a G3RV-SL500 series. G3RV-SL700 7 mm G3RV-SL500 12 mm Fig. 1 Exposed Conductor Length Wiring Procedure for G3RV-SL500 series Screwdriver hole Wire connection hole...
Precautions Precautions for Connection • If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. • Do not move the screwdriver up, down, or from side to side while it •...
● Handling Definition of Precautionary Information • Be sure to provide adequate air flow to G3RV. Failure to do so can cause the G3RV to overheat leading to short circuit and Indicates a potentially hazardous situation which, burning. if not avoided, will result in minor or moderate WARNING injury, or may result in serious injury or death.
Suitability for Use OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the product.