Page 1
4,000 V between input and load. • Certified by UL, CSA, and VDE (reinforced insulation). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Solid State Relays.
G3PA Ordering Information ■ List of Models Model Isolation Zero cross function Indicator Rated output load Rated input voltage G3PA-240B-VD Phototriac 40 A at 24 to 240 VAC 5 to 24 VDC coupler G3PA-260B-VD 60 A at 24 to 240 VAC G3PA-420B-VD 20 A at 200 to 400 VAC 12 to 24 VDC...
G3PA Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input Model Rated voltage Operating Voltage Input current Voltage level range impedance Must operate voltage Must release voltage G3PA-240B-VD 5 to 24 VDC 4 to 30 VDC 7 mA max. 4 VDC max.
Page 4
G3PA ■ Characteristics Item G3PA- G3PA- G3PA- G3PA- G3PA- G3PA- G3PA- 240B-VD 260B-VD 420B-VD 420B-VD-2 430B-VD 430B-VD-2 450B-VD-2 Operate time 1/2 of load power source cycle + 1 ms max. (DC Input, -B models) 1 1/2 of load power source cycle + 1 ms max. (AC Input) 1 ms max.
G3PA Operation ■ Replacement Parts G32A-A Power Device Cartridge The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red, the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement. The damaged cartridge can be replaced with a new one without disconnecting the wires from the G3PA.
Page 6
G3PA ■ Replacement Procedure G32A-A420-VD(-2) To remove or replace the Power Device Cartridge, use the special tool provided with it for extraction. (Do not switch on the power without the Power Device Cartridge. For details, see the attached the instruction sheet with the product.) Extraction Follow the procedures below to dismount the Power Device Cartridge from the G3PA.
Page 7
G3PA 3. Insert the cartridge into the opening of the G3PA so that side A 4. Tighten the screws on both the corners with a tightening torque of and side B are even. 0.59 to 0.78 N·m. 5. Tighten the screws on both the sides with a tightening torque of 0.59 to 0.78 N·m.
G3PA Engineering Data Load Current vs. Ambient Temperature Vertical Mounting Panel Ground G3PA-240B-VD G3PA-260B-VD Ambient temperature (°C) Ambient temperature (°C) For close mounting of two or three SSRs, limit the load current to 90% or less. G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 G3PA-450B-VD-2 Ambient temperature (°C) Ambient temperature (°C)
G3PA Input Voltage vs. Input Current G3PA-2@0B-VD(-X) G3PA-4@0-VD, G3PA-4@-VD-2 T = 25°C Ta = 25°C Input current Input current Input impedance Input impedance Input voltage (V) Input voltage (V) Horizontal Mounting Panel Ground G3PA-240B-VD G3PA-260B-VD −30 −20 Ambient temperature (°C) Ambient temperature (°C) G3PA-450B-VD-2 G3PA-420B-VD, G3PA-430B-VD...
Page 10
G3PA Close Mounting (Up to Three) Panel Ground DIN track G3PA-240B-VD G3PA-260B-VD Ambient temperature (°C) Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 −30 −30 Ambient temperature (°C) Ambient temperature (°C) G3PA-450B-VD-2 Ambient temperature (°C)
Page 11
G3PA One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. G3PA-420B-VD, G3PA-420B-VD-2 G3PA-240B-VD/260B-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2 Energized time (ms) Energized time (ms)
Page 12
G3PA Dimensions Note: All units are in millimeters unless otherwise indicated. G3PA-420B-VD, G3PA-420B-VD-2 Without Terminal With Terminal Mounting Holes Terminal Arrangement/ Cover Cover Internal Connections Two, 4.5 dia. or M4 4.6 dia. Two, M4 90±0.2 Linking terminal 90±0.3 max. Linking terminal −B2 Two, M3.5...
G3PA Safety Precautions ■ Precautions for Correct Use Load Please observe the following precautions to prevent failure to Load power Input operate, malfunction, or undesirable effect on product performance. supply Load Connection When attaching a heat sink to the G3PA-(VD), in order to facilitate heat dissipation, apply silicone grease or equivalent heat-conductive For an AC load, use a power supply rated at 50 or 60 Hz.
G3PA Close Mounting A heat exchanger, if used, should be located in front of the SSR Units to ensure the efficiency of the heat exchanger. SSR Mounting Pitch Please reduce the ambient temperature of SSRs. The rated load current of an SSR is measured at an ambient Panel Mounting (At a rated ambient temperature of 40°C).
Page 15
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied.