• The protect function restricts key use to prevent unwanted key operation. Before
changing parameters in this mode, first make sure that protecting the keys will
not cause any problems in operation.
• To select this mode, press the
minimum. To exit this mode, press the
again for 1 second minimum.
• The following table shows the parameters supported in this mode and the page
where the parameter is described.
Security
• This parameter specifies which parameters are protected. Note that the protect
mode and manual mode cannot be protected.
Function
• Only the modes indicated by the "F" mark in the table below can be selected on
the menu display. For example, when this parameter is set to "3", only levels 0 and
1 and the program mode can be selected.
Setting
• When this parameter is set to "0", the protection function is disabled.
• When this parameter is set to "5", only the parameters in the level 0 mode can be
used, and the menu display is not selected.
• When this parameter is set to "6", "PV/Present SP" parameter can only be dis-
played. (The set point cannot be changed.)
• Default is "1". (Only the calibration mode is protected.)
F Related description
3.6 Protect Mode (page 3-19)
See
RUN/RST
Symbol
Security
Key protect
Mode
Mode
0
Calibration
F
Option
F
Expansion
F
Setup
F
Level 2
F
Level 1
F
Program
F
Level 0
F
*1 The "PV/Present SP" parameter is only displayed.
and
keys simultaneously for 1 second
and
RUN/RST
Parameter Name
Setting value
1
2
3
4
5
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
Protect Mode
keys simultaneously
Page
5-3
5-4
6
*1
5--3
Need help?
Do you have a question about the E5AK PROGRAMMABLE TYPE and is the answer not in the manual?