Batch Flowrate Capture (Block Model 014)

6-18-2 Tuning Screens

112
This section describes only the differences between the tuning screens in the
Batch Flowrate Capture Block and Basic PID Block (Block Model 011). For
details on the areas not covered here, refer to 6-1-2 Tuning Screens.
7
1: Parameter Settings
These fields are used to display and set each parameter for Batch Flowrate
Capture processing.
Parameter
Overrun setting
B0 (032)
(The setting address is a working address.)
Pre-batch setting
BP (033)
(The setting address is a working address.)
Flowrate limitation
B1 (034)
(The setting address is a working address.)
MV index position
MV_IDX (098)
Numeral Display and Input objects are used to create these fields, and a ten-
key pad is displayed when a field is touched.
The following table shows the upper and lower limits of the setting ranges.
Parameter
Overrun setting
0
Pre-batch setting
0
Flowrate limitation
0
−15.00
MV index position
The following table shows the units that are displayed. These units are fixed.
Parameter
Overrun setting
None
Pre-batch setting
None
Flowrate limitation
None
MV index position
%
6
Referenced tag ITEM
Lower limit
9999
9999
9999
115.0
Unit
Section 6-18
Upper limit