Omron CQM1H - 08-2005 Operation Manual page 76

Programmable controllers; inner boards
Hide thumbs Also See for CQM1H - 08-2005:
Table of Contents

Advertisement

Input Unit Specifications
IR 00000 to IR 00015 are always allocated to the CPU Unit's 16 built-in input
points.
• Inputs IN0 to IN 3 (corresponding to IR 00000 to IR 00003) can be set in
the PC Setup to be used as input interrupts.
• Inputs IN4 to IN7 (corresponding to IR 00004 to 00007) can be used as
high-speed counter 0.
Terminal
Input
number
B0
IN0
A0
IN1
B1
IN2
A1
IN3
B2
IN4
A2
IN5
B3
IN6
A3
IN7
to
to
B7
IN14
A7
IN15
Note If IN0 through IN3 are set for use as input interrupts in the PC Setup, the ON
and OFF delays for input interrupts are fixed at 0.1 ms max. and 0.5 ms max.,
respectively. If IN4 through IN6 are set for use as high-speed counter inter-
rupts, the delays for high-speed counters are as shown in the following table.
Input
IN4 (A)
5 kHz
IN5 (B)
Normal input
ON: 100 µs min. required; OFF delay: 500 µs min. required
IN6 (Z)
Input bit
IR 00000
Normal inputs or input interrupts (Input
Interrupt Mode or Counter Mode): set in
IR 00001
PC Setup (DM 6628).
IR 00002
IR 00003
IR 00004
Normal inputs or high-speed counter 0:
set in PC Setup (DM 6642).
IR 00005
IR 00006
IR 00007
Only usable as normal inputs.
to
IR 00014
IR 00015
Incrementing mode
Section 2-2
Function
Differential phase mode
2.5 kHz
51