Technical Data; Datasheet - YASKAWA Solectria PVI-36TL-480-V2 Installation And Operation Manual

Commercial 1000vdc string inverters
Table of Contents

Advertisement

Installation and Operation Guide SOLECTRIA® PVI 25TL-208, PVI 36TL-480-V2, PVI 50TL-480 and PVI 60TL-480
11.

Technical Data

Datasheet

MODEL NAME
DC INPUT
MAX. PV POWER
MAX. DC INPUT VOLTAGE
OPERATING DC INPUT
VOLTAGE RANGE
START-UP DC INPUT VOLTAGE
/ POWER
NUMBER OF MPP TRACKERS
MPPT VOLTAGE RANGE
MAX. PV SHORT-CIRCUIT
CURRENT
(ISC X 1.25)
NUMBER OF DC INPUTS
DC DISCONNECTION TYPE
DC SURGE PROTECTION
AC OUTPUT
RATED AC OUTPUT POWER
MAX. AC APPARENT POWER
RATED OUTPUT VOLTAGE
OUTPUT VOLTAGE RANGE
GRID CONNECTION TYPE
MAX. AC OUTPUT CURRENT
@OPERATING
V
AC
MAX AC OCPD RATING
RATED OUTPUT FREQUENCY
OUTPUT FREQUENCY RANGE
POWER FACTOR
CURRENT THD
MAX. FAULT CURRENT
CONTRIBUTION (1 CYCLE RMS)
AC DISCONNECTION TYPE
AC SURGE PROTECTION
Note 1: The "Output Voltage Range" and "Output Frequency Range may differ according to the chosen grid
standard.
DOCR-071086-C (04/12/2024)
PVI 25TL-208
45kW (17kW per
MPPT)
480-850V
DC
135A (45A per
MPPT)
6 inputs, 2 per
MPPT
25kW
25kVA
208V
AC
183-229V
AC
69.5A@208
VAC
125A
1
64.1A
Type II MOV,
1240V
, 15kA
C
I
(8/20μS)
TM
PVI-36TL-480-V2
61.2kW (22.44kW
per MPPT)
1000V
DC
200-950V
330V / 80W
3
400-850V
DC
204A (68A per MPPT)
15 inputs, 5 per MPPT
Load-rated DC switch
Type II MOV, 2800V
, 20kA I
C
36kW
36kVA
50kVA/55kVA
3Φ/PE/N (Physical Neutral optional)
43.5A@480
60.2A/66.2A@480
VAC
125A
Suggested 125A
60Hz
57-63Hz
>0.99 (±0.8 adjustable)
<3%
73.2A
Load-rated AC switch
Type II MOV
PVI 50TL-480
PVI 60TL-480
90kW (33kW per MPPT)
DC
480-850V
540-850V
DC
(8/20μS)
TM
50kW
60kVA/66kVA
480V
AC
422-528V
AC
72.2A/79.4A@480
VAC
Suggested 125A
64.1A
Page 124 of 136
DC
60kW
VAC