2-1 Installation environment

 Locations free of water droplets, vapors, dust and oily dust.
 Non-corrosive, flammable gas and liquid.
 No floating dust metal particles.
 Strong and vibration-free place.
 The environment temperature is -10 °C ∼ 50 °C. If the environment temperature exceeds 40 °C,
 Locations without electromagnetic noise interference.
please place it in a well ventilated place and delate the inverter.

2-2 Installation method and space

 The inverter should be installed on a structure that does not burn, such as metal, otherwise a fire
accident may occur.
 The inverter should be installed vertically and securely with screws. Do not flip, tilt or install
horizontally. When the inverter runs, heat is generated. To ensure the passage of the cooling air, a
certain space is left during installation (as shown in the figure).
 When installing the inverter in the control cabinet, consider ventilation and heat dissipation to
ensure that the ambient temperature of the inverter does not exceed the specified value. Do not
install the inverter in a closed box with poor ventilation.
 When installing multiple inverters in the same control cabinet, it is recommended to install them
side by side in order to reduce the thermal impact between each other. If it is necessary to install
up and down, a partition plate must be provided to reduce the influence of heat generated in the
lower part on the upper part (as shown in the figure).
 Do not allow foreign matter such as various fibers, paper sheets, chips (chips) or metal fragments
to enter the inverter.

Chapter 2 Installation

Chapter 2 Installation
Single installation diagram
Power level
≤15kw
18.5~30kw
≥37kw
Upper and lower installation
Installation size
A
≥20mm
≥100mm
≥50mm
≥200mm
≥50mm
≥300mm
5